Marginal bone loss around axial and straight implants supported with prefabricated SFI-Bar with mandibular overdentures.
Autor: | Balehonnur P; Department of Prosthodontics, Government dental college and research Institute, Bangalore, Karnataka, India., Awinashe VN; Department of Prosthodontics, College of dentistry in Ar Rass, Qassim University, Kingdom of Saudi Arabia., Parihar AS; Department of Periodontology and Oral Implantology, Peoples Dental Academy Bhopal, MP, India., Balaji DL; Department of Prosthodontics, Priyadarshini Dental College and Hospital,Thiruvallur, 631203, India., Kochhar AS; Department of Prosthodontics, Government dental college and research Institute, Bangalore, Karnataka, India., Mehndiratta R; Department of Prosthodontics, Government dental college and research Institute, Bangalore, Karnataka, India. |
---|---|
Jazyk: | angličtina |
Zdroj: | Bioinformation [Bioinformation] 2021 Jan 31; Vol. 17 (1), pp. 289-294. Date of Electronic Publication: 2021 Jan 31 (Print Publication: 2021). |
DOI: | 10.6026/97320630017289 |
Abstrakt: | To assess the role of prefabricated SFI-Bar in peri-implant bone loss around immediately axially loaded and straight implants. This study comprised of 40 complete denture wearer patients who received two axially parallel implants connected by SFI-Bars in group I and two 15° mesially tilted implants connected by SFI-Bars in group II. Peri- implant bone loss (PiBL) was measured at 1 year, 2 years and 3 years. The mean PiBL at 1 year in group I was 0.21 mm and I group II was 0.22, at 2 years in group I was 0.26 mm and in group II was 0.23 mm and at 3 years, in group I was 0.29 mm and in group II was 0.34 mm. The difference was significant at 3 years (P< 0.05). The mean mesial PIBL at 1 year in group I was 0.18 mm, in group II was 0.20 mm, at 2 years in group I was 0.19 mm and in group II was 0.07 mm and at 3 years, in group I was 0.25 mm and in group II was 0.29 mm. The difference found to be significant in each time duration in both groups (P< 0.05).The mean distal PIBL at 1 year in group I was 0.23 mm, in group II was 0.22 mm, at 2 years in group I was 0.33 mm and in group II was 0.39 mm and at 3 years, in group I was 0.34 mm and in group II was 0.39 mm. The difference found to be significant at 2 and 3 years in both groups (P< 0.05). Authors found that mandibular overdentures retained with Prefabricated SFI-Bar with axial and straight inserted implants may be useful in patients with reduced bone height. (© 2021 Biomedical Informatics.) |
Databáze: | MEDLINE |
Externí odkaz: |