Functional Expression of a Mo-Cu-Dependent Carbon Monoxide Dehydrogenase (CODH) and Its Use as a Dissolved CO Bio-microsensor.

Autor: Reginald SS; School of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology, 261 Cheomdan-gwagiro, Buk-gu, Gwangju 61005, Republic of Korea., Etzerodt M; Department of Molecular Biology and Genetics, Aarhus University, Gustav Wieds Vej 10, Aarhus 8000, Denmark., Fapyane D; Aarhus University Centre of Water Technology (WATEC), Department of Bioscience, Aarhus University, Ny Munkegade 116, Aarhus 8000, Denmark., Chang IS; School of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology, 261 Cheomdan-gwagiro, Buk-gu, Gwangju 61005, Republic of Korea.
Jazyk: angličtina
Zdroj: ACS sensors [ACS Sens] 2021 Jul 23; Vol. 6 (7), pp. 2772-2782. Date of Electronic Publication: 2021 Jul 12.
DOI: 10.1021/acssensors.1c01243
Abstrakt: Herein, we report the heterologous expression in Escherichia coli of a Mo-Cu-containing carbon monoxide dehydrogenase (Mo-Cu CODH) from Hydrogenophaga pseudoflava , which resulted in an active protein catalyzing CO oxidation to CO 2 . By supplying the E. coli growth medium with Na 2 MoO 4 (Mo) and CuSO 4 (Cu), the Mo-Cu CODH metal cofactors precursors, the expressed L-subunit was found to have CO-oxidation activity even without the M- and S- subunits. This successful expression of CO-oxidizing-capable single L-subunit provides direct evidence of its role as the catalytic center of Mo-Cu CODH that has not been discovered and studied before. Subsequently, we used the expressed protein to construct a CO bio-microsensor based on a newly developed fast and sensitive Clark-type CO 2 transducer using an aprotic solvent/ionic liquid electrolyte. The CO bio-microsensor exhibited a linear response to CO concentration in the 0-9 μM range, with a limit of detection (LOD) of 15 nM CO. The sensor uses a mixture of Mo-Cu CODH's L-subunit/Mo, Cu cofactors/methylene blue, confined in the enzyme chamber that is placed in front of a CO 2 transducer. The optimized sensor's sensitivity and performance were retained to levels of at least 80% for 1 week of continuous polarization and operation in an aqueous medium. We have also demonstrated the use of an alkaline front-trap solution to make a completely O 2 /CO 2 interference-free microsensor. The CO bio-microsensor developed in this study is potentially useful as an analytical tool for the detection of trace CO in dissolved form for monitoring dissolved CO concentration dynamics in natural or synthetic systems.
Databáze: MEDLINE