A Rare Presentation of Extensor Pollicis Longus Tendon Rupture After Nondisplaced Scaphoid Fracture.
Autor: | Henry TW; Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA., Lutsky KF; Rothman Orthopaedic Institute, Philadelphia, PA. Electronic address: lutskyk1@gmail.com. |
---|---|
Jazyk: | angličtina |
Zdroj: | The Journal of hand surgery [J Hand Surg Am] 2022 May; Vol. 47 (5), pp. 483.e1-483.e3. Date of Electronic Publication: 2021 Apr 23. |
DOI: | 10.1016/j.jhsa.2021.03.013 |
Abstrakt: | Extensor pollicis longus tendon rupture is a reported complication after nondisplaced distal radius fractures. These are thought to occur secondary to mechanical irritation or compromised blood supply. We present a case of extensor pollicis longus rupture after a healed nondisplaced scaphoid fracture, which may have involved a similar attritional process. We are unaware of any prior reports of extensor pollicis longus rupture after this type of injury. (Copyright © 2022 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |