The 1-Megapixel pnCCD detector for the Small Quantum Systems Instrument at the European XFEL: system and operation aspects.
Autor: | Kuster M; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Ahmed K; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Ballak KE; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Danilevski C; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Ekmedžić M; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Fernandes B; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Gessler P; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Hartmann R; PNSensor GmbH, Otto-Hahn-Ring 6, 81739 München, Germany., Hauf S; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Holl P; PNSensor GmbH, Otto-Hahn-Ring 6, 81739 München, Germany., Meyer M; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Montaño J; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Münnich A; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Ovcharenko Y; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Rennhack N; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Rüter T; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Rupp D; Max-Born-Institute, Max-Born-Straße 2A, 12489 Berlin, Germany., Schlosser D; PNSensor GmbH, Otto-Hahn-Ring 6, 81739 München, Germany., Setoodehnia K; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Schmitt R; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany., Strüder L; PNSensor GmbH, Otto-Hahn-Ring 6, 81739 München, Germany., Tanyag RMP; Max-Born-Institute, Max-Born-Straße 2A, 12489 Berlin, Germany., Ulmer A; IOAP, Technische Universität Berlin, Hardenbergstraße 36, 10623 Berlin, Germany., Yousef H; European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of synchrotron radiation [J Synchrotron Radiat] 2021 Mar 01; Vol. 28 (Pt 2), pp. 576-587. Date of Electronic Publication: 2021 Jan 28. |
DOI: | 10.1107/S1600577520015659 |
Abstrakt: | The X-ray free-electron lasers that became available during the last decade, like the European XFEL (EuXFEL), place high demands on their instrumentation. Especially at low photon energies below 1 keV, detectors with high sensitivity, and consequently low noise and high quantum efficiency, are required to enable facility users to fully exploit the scientific potential of the photon source. A 1-Megapixel pnCCD detector with a 1024 × 1024 pixel format has been installed and commissioned for imaging applications at the Nano-Sized Quantum System (NQS) station of the Small Quantum System (SQS) instrument at EuXFEL. The instrument is currently operating in the energy range between 0.5 and 3 keV and the NQS station is designed for investigations of the interaction of intense FEL pulses with clusters, nano-particles and small bio-molecules, by combining photo-ion and photo-electron spectroscopy with coherent diffraction imaging techniques. The core of the imaging detector is a pn-type charge coupled device (pnCCD) with a pixel pitch of 75 µm × 75 µm. Depending on the experimental scenario, the pnCCD enables imaging of single photons thanks to its very low electronic noise of 3 e - and high quantum efficiency. Here an overview on the EuXFEL pnCCD detector and the results from the commissioning and first user operation at the SQS experiment in June 2019 are presented. The detailed descriptions of the detector design and capabilities, its implementation at EuXFEL both mechanically and from the controls side as well as important data correction steps aim to provide useful background for users planning and analyzing experiments at EuXFEL and may serve as a benchmark for comparing and planning future endstations at other FELs. (open access.) |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |