Ultrasensitive immunoassay allows measurement of serum neurofilament heavy in multiple sclerosis.

Autor: Verberk IMW; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands. Electronic address: i.verberk@amsterdamumc.nl., Koel-Simmelink M; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands., Twaalfhoven H; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands., Vrenken H; Department of Radiology, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands., Korth C; Department of Neuropathology, Heinrich Heine University Düsseldorf, Düsseldorf, Germany., Killestein J; Multiple Sclerosis center Amsterdam, Department of neurology, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands., Teunissen CE; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands., Bridel C; Neurochemistry Laboratory, Department of Clinical Chemistry, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands; Department of Clinical Neurosciences, Neurology Unit, Geneva University Hospital, Geneva, Switzerland.
Jazyk: angličtina
Zdroj: Multiple sclerosis and related disorders [Mult Scler Relat Disord] 2021 May; Vol. 50, pp. 102840. Date of Electronic Publication: 2021 Feb 10.
DOI: 10.1016/j.msard.2021.102840
Abstrakt: Background: Neurofilament heavy (NfH) is a promising biomarker for neuro-axonal damage in Multiple Sclerosis (MS). We compared the performance of high-sensitivity serum-NfH immunoassays, with as aim to investigate the value of serum-NfH as biomarker for MS.
Methods: We measured serum-NfH in 76 MS patients with Simoa (one commercial, one in-house) or Luminex assays. Serum-NfH measured by the immunoassay with greatest sensitivity was related to clinical and radiological outcomes with age and sex-adjusted linear regression analysis, and to biological outcomes cerebrospinal fluid (CSF)-NfH, serum neurofilament light (NfL) and CSF-NfL with Spearman's correlation analysis.
Results: With the commercial Simoa assay, we obtained 100% serum-NfH detectability (in-house Simoa: 70%, Luminex: 61%), with lowest coefficient of variation (CV) between duplicates of 11%CV (in-house Simoa: 22%CV, Luminex: 30%CV). Serum-NfH quantified with the commercial Simoa assay was associated with disease duration (standardized beta (sβ) = 0.28, p = 0.034), T2 lesion volume (sβ = 0.23, p = 0.041), and tended to associate with black hole count (sβ = 0.21, p = 0.084) but not with Expanded Disease Disability Score (EDSS) or normalized brain volume (all: p>0.10). Furthermore, serum-NfH showed correlations with CSF-NfH (rho = 0.27, p = 0.018) and serum-NfL (rho=0.44, p < 0.001), but not with CSF-NfL.
Conclusions: Serum-NfH can be quantified with high-sensitivity technology. Cross-sectionally, we observed some weak correlations of serum-NfH with MS disease burden parameters, suggesting there might be some utility for serum-NfH as biomarker for MS disease burden.
(Copyright © 2021 The Authors. Published by Elsevier B.V. All rights reserved.)