Calipered kinematic alignment technique for implanting a Medial Oxford®: A technical note.
Autor: | Rivière C; MSK Lab, Imperial College London, Sir Michael Uren Hub, White City Campus 86, Wood Lane, W12 0BZ, London, UK; Personalized Arthroplasty Society Montréal, Canada; Clinique du Sport, 04, rue Georges-Negrevergne, 33700 Mérignac, France; The Lister Hospital, Chelsea Bridge rd, London, UK. Electronic address: c.riviere@imperial.ac.uk., Logishetty K; MSK Lab, Imperial College London, Sir Michael Uren Hub, White City Campus 86, Wood Lane, W12 0BZ, London, UK., Villet L; Personalized Arthroplasty Society Montréal, Canada; Clinique du Sport, 04, rue Georges-Negrevergne, 33700 Mérignac, France., Maillot C; Service de Chirurgie Orthopedique et Traumatologique Bichat-Beaujon, Assistance publique-Hopitaux de Paris, université Sorbonne Paris Cité, Paris, France. |
---|---|
Jazyk: | angličtina |
Zdroj: | Orthopaedics & traumatology, surgery & research : OTSR [Orthop Traumatol Surg Res] 2021 May; Vol. 107 (3), pp. 102859. Date of Electronic Publication: 2021 Feb 16. |
DOI: | 10.1016/j.otsr.2021.102859 |
Abstrakt: | This note describes a surgical technique to kinematically align a medial Oxford® UKA. Applying kinematic alignment principles is an alternative, personalised, physiological, and potentially clinically advantageous method for implanting the medial Oxford® UKA. Further investigations are needed to better define the reproducibility and clinical impact of this new surgical technique. (Copyright © 2021 Elsevier Masson SAS. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |