Diagnosis of Systemic Diseases Using Infrared Spectroscopy: Detection of Iron Overload in Plasma-Preliminary Study.
Autor: | Leal LB; Department of Physiological Sciences, Federal University of Espírito Santo (UFES), Marechal Campos Ave, 1468, Maruípe, Vitória, Espírito Santo, 29040-090, Brazil. leal.leob@gmail.com., Nogueira MS; Tyndall National Institute/University College Cork - Lee Maltings Complex, Dyke Parade, Cork, T12R5CP, Ireland., Mageski JGA; Department of Physiological Sciences, Federal University of Espírito Santo (UFES), Marechal Campos Ave, 1468, Maruípe, Vitória, Espírito Santo, 29040-090, Brazil., Martini TP; Institute of Science and Technology, Federal University of Sao Paulo, São José dos Campos, Brazil., Barauna VG; Department of Physiological Sciences, Federal University of Espírito Santo (UFES), Marechal Campos Ave, 1468, Maruípe, Vitória, Espírito Santo, 29040-090, Brazil., Dos Santos L; Department of Physiological Sciences, Federal University of Espírito Santo (UFES), Marechal Campos Ave, 1468, Maruípe, Vitória, Espírito Santo, 29040-090, Brazil., de Carvalho LFDCES; Universidade de Taubaté. R. dos Operários, 09 - Centro, Taubaté, São Paulo, 12020-340, Brazil.; Centro Universitário Braz Cubas, Av. Francisco Rodrigues Filho, 1233 - Vila Mogilar, Mogi das Cruzes, São Paulo, Brazil. |
---|---|
Jazyk: | angličtina |
Zdroj: | Biological trace element research [Biol Trace Elem Res] 2021 Oct; Vol. 199 (10), pp. 3737-3751. Date of Electronic Publication: 2021 Jan 07. |
DOI: | 10.1007/s12011-020-02510-3 |
Abstrakt: | Despite the important role of iron in cellular homeostasis, iron overload (IO) is associated with systemic and tissue deposits which damage several organs. In order to reduce the impact caused by IO, invasive diagnosis exams (e.g., biopsies) and minimally invasive methods were developed including computed tomography and magnetic resonance imaging. However, current diagnostic methods are still time-consuming and expensive. A cost-effective solution is using Fourier-transform infrared spectroscopy (FTIR) for real-time and molecular-sensitive biofluid analysis during conventional laboratory exams. In this study, we performed the first evaluation of the accuracy of FTIR for IO diagnosis. The study was performed by collecting FTIR spectra of plasma samples of five rats intravenously injected with iron-dextran and five control rats. We developed a classification model based on principal component analysis and supervised methods including J48, random forest, multilayer perceptron, and radial basis function network. We achieved 100% accuracy for the classification of the IO status and provided a list of possible biomolecules related to the vibrational modes detected. In this preliminary study, we give a first step towards real-time diagnosis for acute IO or intoxication. Furthermore, we have expanded the literature knowledge regarding the pathophysiological changes induced by iron overload. (© 2021. Springer Science+Business Media, LLC, part of Springer Nature.) |
Databáze: | MEDLINE |
Externí odkaz: |