The Michigan Vision-Related Anxiety Questionnaire: A Psychosocial Outcomes Measure for Inherited Retinal Degenerations.
Autor: | Lacy GD; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Abalem MF; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA; Department of Ophthalmology and Otolaryngology, University of São Paulo Medical School, São Paulo, Brazil., Andrews CA; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Abuzaitoun R; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Popova LT; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Santos EP; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Yu G; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Rakine HY; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Baig N; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Ehrlich JR; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Fahim AT; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Branham KH; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Swenor BK; Johns Hopkins University Wilmer Eye Institute, Baltimore, Maryland, USA., Lichter PR; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA., Dagnelie G; Johns Hopkins University Wilmer Eye Institute, Baltimore, Maryland, USA., Stelmack JA; Illinois Eye and Ear Infirmary, Chicago, Illinois, USA., Musch DC; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA; Department of Epidemiology, School of Public Health, University of Michigan, Ann Arbor, Michigan, USA., Jayasundera KT; Kellogg Eye Center, Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, Michigan, USA. Electronic address: thiran@med.umich.edu. |
---|---|
Jazyk: | angličtina |
Zdroj: | American journal of ophthalmology [Am J Ophthalmol] 2021 May; Vol. 225, pp. 137-146. Date of Electronic Publication: 2020 Dec 09. |
DOI: | 10.1016/j.ajo.2020.12.001 |
Abstrakt: | Objective: We sought to construct and validate a patient-reported outcome measure for screening and monitoring vision-related anxiety in patients with inherited retinal degenerations. Design: Item-response theory and graded response modeling to quantitatively validate questionnaire items generated from qualitative interviews and patient feedback. Methods: Patients at the Kellogg Eye Center (University of Michigan, Ann Arbor, Michigan, USA) with a clinical diagnosis of an inherited retinal degeneration (n = 128) participated in an interviewer-administered questionnaire. The questionnaire consisted of 166 items, 26 of which pertained to concepts of "worry" and "anxiety." The subset of vision-related anxiety questions was analyzed by a graded response model using the Cai Metropolis-Hastings Robbins-Monro algorithm in the R software mirt package. Item reduction was performed based on item fit, item information, and item discriminability. To assess test-retest variability, 25 participants completed the questionnaire a second time 4 to 16 days later. Results: The final questionnaire consisted of 14 items divided into 2 unidimensional domains: rod function anxiety and cone function anxiety. The questionnaire exhibited convergent validity with the Patient Health Questionnaire for symptoms of depression and anxiety. This vision-related anxiety questionnaire has high marginal reliability (0.81 for rod-function anxiety, 0.83 for cone-function anxiety) and exhibits minimal test-retest variability (ρ = 0.81 [0.64-0.91] for rod-function anxiety and ρ = 0.83 [0.68-0.92] for cone-function anxiety). Conclusions: The Michigan Vision-Related Anxiety Questionnaire is a psychometrically validated 14-item patient-reported outcome measure to be used as a psychosocial screening and monitoring tool for patients with inherited retinal degenerations. It can be used in therapeutic clinical trials for measuring the benefit of an investigational therapy on a patient's vision-related anxiety. (Copyright © 2021 Elsevier Inc. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |