Improving the Voltammetric Determination of Hg(II): A Comparison Between Ligand-Modified Glassy Carbon and Electrochemically Reduced Graphene Oxide Electrodes.

Autor: Raicopol MD; Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061 Bucharest, Romania., Pandele AM; Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061 Bucharest, Romania., Dascălu C; Faculty of Applied Sciences, University Politehnica of Bucharest, 313 Splaiul Independenţei, 060042 Bucharest, Romania., Vasile E; Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061 Bucharest, Romania., Hanganu A; Department of Organic Chemistry, Biochemistry and Catalysis, University of Bucharest, 90-92 Sos. Panduri, 050657 Bucharest, Romania., Vasile GG; National Research and Development Institute for Industrial Ecology ECOIND Bucharest, 71-73 Drumul Podul Dambovitei Street, 060652 Bucharest, Romania., Bugean IG; Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061 Bucharest, Romania., Pirvu C; Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061 Bucharest, Romania., Stanciu G; Department of Chemistry and Chemical Engineering, Ovidius University, 124 Mamaia Blvd, 900527 Constanta, Romania., Buica GO; Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061 Bucharest, Romania.
Jazyk: angličtina
Zdroj: Sensors (Basel, Switzerland) [Sensors (Basel)] 2020 Nov 28; Vol. 20 (23). Date of Electronic Publication: 2020 Nov 28.
DOI: 10.3390/s20236799
Abstrakt: A new thiosemicarbazone ligand was immobilized through a Cu(I)-catalyzed click reaction on the surface of glassy carbon (GC) and electrochemically reduced graphene oxide (GC-ERGO) electrodes grafted with phenylethynyl groups. Using the accumulation at open circuit followed by anodic stripping voltammetry, the modified electrodes showed a significant selectivity and sensibility for Hg(II) ions. A detection limit of 7 nM was achieved with the GC modified electrodes. Remarkably, GC-ERGO modified electrodes showed a significantly improved detection limit (0.8 nM), sensitivity, and linear range, which we attribute to an increased number of surface binding sites and better electron transfer properties. Both GC and GC-ERGO modified electrodes proved their applicability for the analysis of real water samples.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje