Optimization and Validation of HS-SPME-GC-MS for the Determination of Furan and Alkylfurans in Chocolate-Based Products: Impact of Tempering and Laser Printing.

Autor: Alsafra Z; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liege, Allée de la Chimie 3, B-6c Sart-Tilman, B-4000 Liege, Belgium., Scholl G; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liege, Allée de la Chimie 3, B-6c Sart-Tilman, B-4000 Liege, Belgium., Eppe G; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liege, Allée de la Chimie 3, B-6c Sart-Tilman, B-4000 Liege, Belgium.
Jazyk: angličtina
Zdroj: Journal of AOAC International [J AOAC Int] 2021 May 21; Vol. 104 (2), pp. 253-259.
DOI: 10.1093/jaoacint/qsaa102
Abstrakt: Background: Furan and its alkyl substituted (2-methylfuran, 3-methylfuran, 2,3-dimethylfuran, 2,5-dimethylfuran) are found in a range between ppm to sub-ppb levels in many foodstuffs undergoing heat treatments like coffee, chicory, or even chocolate.
Objectives: Two major objectives are presented. First, we aim at optimizing and validating a HS-SPME-GC-MS method for the quantification of five alkylfurans in chocolate. Second, we focus our study on measuring the quantitative impact of engraving technique on the formation of furan and its derivatives in chocolate, from the raw callets to processed end-products.
Method: HS-SPME-GC-MS method operating in SIM mode and using isotope dilution technique with deuterated homologue internal standards was used to quantify alkylfurans in chocolate.
Results: Good repeatability (RSD% = 0.1-8%, in duplicate) and intermediate precision (RSD% = 1.7-7%, n = 6) were obtained for these five process contaminants at 10, 25, and 50 µg/kg. Trueness was varying between 81 and 109%. LoQ ranged from 0.48 to 2.50 µg/kg. Relative expanded measurement uncertainties ranged from 6 to 30%. Finally, tempering is responsible for a 24% increase in furan contamination, while the laser engraving technique results in an additional 31% increase in furan. A similar trend was also observed for 2-methylfuran and 3-methylfuran, whereas no significant increases were observed for 2,3-dimethylfuran and 2,5-dimethylfuran.
Conclusions and Highlights: A reliable and sensitive method of HS-SPME-GC-MS was reported for the first time for the analysis of furan and four alkylfurans in chocolate. This paper demonstrated that engraving using laser-based techniques can increase the levels of these compounds by up to 30%.
(© AOAC INTERNATIONAL 2020. All rights reserved. For permissions, please email: journals.permissions@oup.com.)
Databáze: MEDLINE