Hydrophilic interaction liquid chromatography coupled to quadrupole time-of-flight mass spectrometry as a potential combination for the determination of sulfonamide residues in complex infant formula matrices.

Autor: Petrarca MH; Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil. Electronic address: petrarcamh@gmail.com., Braga PAC; Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil., Reyes FGR; Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil., Bragotto APA; Department of Food Science, School of Food Engineering, University of Campinas (UNICAMP), Rua Monteiro Lobato, 80, 13083-862, Campinas, SP, Brazil.
Jazyk: angličtina
Zdroj: Journal of chromatography. A [J Chromatogr A] 2020 Dec 06; Vol. 1633, pp. 461606. Date of Electronic Publication: 2020 Oct 10.
DOI: 10.1016/j.chroma.2020.461606
Abstrakt: An accurate, sensitive and selective analytical method is proposed for sulfonamide residues analysis in infant formulas based on hydrophilic interaction liquid chromatography (HILIC) and quadrupole time-of-flight mass spectrometry in full scan mode. The sample preparation approach involves low-temperature lipid precipitation followed by dispersive solid-phase extraction with PSA and C 18 sorbents, which was successfully optimized using Plackett-Burman design. In order to achieve high analytical sensitivity, the influence of HILIC conditions on sulfonamide ionization was investigated, such as the mobile phase composition, buffer concentration, and sample diluent for injection. The method performance characteristics, including linearity (range 5-120 µg kg -1 ), reliable limits of quantification (between 5 and 20 µg kg -1 ), recovery (72.9-109.2%) and precision (coefficient of variation values ≤ 19.8%) under repeatability and within-laboratory reproducibility conditions, were in accordance with the Codex Alimentarius Commission CAC/GL 71-2009 for quantitative analytical methods for veterinary drug residues in foods. Moreover, adequate identification of the compounds was provided with accurate mass measurement of both precursor and fragment ions in one single run. Finally, the developed method was applied to thirty-five powdered milk-based infant formula samples available in the Brazilian market.
Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2020. Published by Elsevier B.V.)
Databáze: MEDLINE