[Correction of corneal astigmatism in femtosecond laser-assisted cataract extraction surgery].

Autor: Kulikova IL; Cheboksary branch of S.N. Fyodorov National Medical Research Center «MNTK «Eye Microsurgery», Cheboksary, Russia., Pashtaev NP; Cheboksary branch of S.N. Fyodorov National Medical Research Center «MNTK «Eye Microsurgery», Cheboksary, Russia.; Postgraduate Doctors' Training Institute, Cheboksary, Russia.; Chuvash State University named after I.N. Ulyanov, Cheboksary, Russia., Timofeyeva NS; Cheboksary branch of S.N. Fyodorov National Medical Research Center «MNTK «Eye Microsurgery», Cheboksary, Russia.
Jazyk: ruština
Zdroj: Vestnik oftalmologii [Vestn Oftalmol] 2020; Vol. 136 (5), pp. 87-95.
DOI: 10.17116/oftalma202013605187
Abstrakt: Purpose: To perform a comparative analysis of clinical and functional results and efficiency of corneal astigmatism correction after femtosecond laser-assisted cataract surgery (FLACS) with implantation of toric intraocular lens (TIOL) and in combination with arcuate keratotomy (FL-AC).
Material and Methods: The examination included 60 patients (60 eyes). The first group consisted of 30 patients (30 eyes) who underwent FLACS with implantation of TIOL (Acrysof IQ Toric, Alcon, U.S.A.); the second group consisted of 30 patients (30 eyes) who underwent FLACS in combination with FL-AC. The examination was carried out before the operation, on the 3 rd day and 3 months after surgery. Corneal astigmatism correction efficiency was analyzed using the Alpins method and graphical vector analysis.
Results: Uncorrected visual acuity (UCVA) indices increased to 0.70±0.24 and 0.66±0.31 in the FLACS with TIOL and FLACS with FL-AC groups, respectively, without statistically significant differences between the groups ( p =0.03). The value of the residual cylinder was significantly lower in the FLACS with TIOL group (-0.77±0.58 and -0.80±0.39) compared with FLACS with FL-AC (-1.08±0.81 and -1.18±0.63) both on day 3 ( p =0.02), and 3 months after surgery ( p =0.02). In the FLACS with TIOL group, a higher correction index (0.99±0.18) and a smaller difference vector (0.77±0.64) were achieved compared to the FLACS with FL-AC group (0.78±0.35 and 1.05±0.76, respectively). Corneal higher-order aberrations (HOA) significantly differed on the 3 rd day after surgery in the 3.0 mm ( p =0.04) and 5.0 mm ( p =0.04) zones between the groups. Endothelial cells density was 2460.50±328.40 and 2526.125±196.74 cl/mm 2 after 3 months of observation in the FLACS with TIOL and FLACS with FL-AC groups, respectively ( p =0.61).
Conclusion: Both methods had comparable visual acuity results ( p =0.03). FLACS with TIOL provided more effective correction of the cylindrical component of refraction to 3.0 D.
Databáze: MEDLINE