Novel noninvasive estimation of mixed venous oxygen saturation by echocardiography and expired gas analysis.

Autor: Onoue T; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Iwataki M; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Araki M; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Akashi J; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Kitano T; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Nabeshima Y; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Hei S; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Nagata Y; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Hayashi A; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Tsuda Y; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Sonoda S; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Fujino Y; Department of Environmental Epidemiology, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan., Levine RA; Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Boston, Massachusetts., Otsuji Y; Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.
Jazyk: angličtina
Zdroj: American journal of physiology. Heart and circulatory physiology [Am J Physiol Heart Circ Physiol] 2020 Nov 01; Vol. 319 (5), pp. H1078-H1086. Date of Electronic Publication: 2020 Sep 18.
DOI: 10.1152/ajpheart.00429.2020
Abstrakt: Mixed venous oxygen (O 2 ) saturation ([Formula: see text]) is an important measure for evaluating the sufficiency of cardiac output (CO) relative to whole body O 2 consumption (V̇o 2 ), while clinical use is limited to the required invasive catheterization. According to Fick's equation, V̇o 2 (mL/min) = CO (L/min) × Hb (g/dL) × 1.36 (mL/g) × ([Formula: see text] - [Formula: see text])/10 (Hb = hemoglobin concentration, [Formula: see text] = arterial blood O 2 saturation). Because V̇o 2 , CO, Hb, and [Formula: see text] can be measured noninvasively with expired gas analysis, echocardiography, a simple blood test, and percutaneous O 2 saturation, respectively, [Formula: see text] can be calculated noninvasively. We hypothesized that noninvasively calculated [Formula: see text] shows a significant correlation and agrees well with invasively measured [Formula: see text]. In 47 patients (29 men; mean age, 70 ± 12 yr) who underwent right heart catheterization, [Formula: see text] was directly measured by sampling pulmonary artery blood. Noninvasively calculated [Formula: see text] was also obtained by the method described above. The calculated [Formula: see text] was significantly correlated with the measured [Formula: see text] ( r  = 0.79, P < 0.001) and was significantly smaller than the measured [Formula: see text] (70 ± 5.1 vs. 72.1 ± 4.9%, P < 0.001). Bias at [Formula: see text] was -2.2% (95% confidence interval, -3.2 to -1.1%) with limits of agreement from -9.5 to 5.2%, demonstrating acceptable agreement. The optimal cutoff value of calculated [Formula: see text] was 69% for reduced measured [Formula: see text] < 70% with an area under the curve of 0.94. Reduced calculated [Formula: see text] < 69% indicated a sensitivity of 92.9% and a specificity of 90.9% for reduced measured [Formula: see text] < 70%. Noninvasive [Formula: see text] calculated from echocardiography, expired gas analysis, percutaneous arterial blood O 2 saturation, and hemoglobin level significantly correlated and agreed well with direct [Formula: see text] measured by catheterization. This novel method allows for practical evaluation of [Formula: see text] to assess the sufficiency of CO according to whole body metabolism. NEW & NOTEWORTHY Clinical use of mixed venous oxygen saturation ([Formula: see text]) is limited to the required invasive procedure. With Fick's equation, expired gas analysis, echocardiography, simple blood tests, and percutaneous oxygen saturation, [Formula: see text] can be calculated noninvasively. We hypothesized that noninvasively calculated [Formula: see text] shows a significant correlation and agrees well with invasively measured [Formula: see text]. The present study examined the relationship between measured [Formula: see text] and calculated [Formula: see text] in patients who underwent right heart catheterization and demonstrated acceptable agreement. This novel method can expand the indication of evaluating [Formula: see text].
Databáze: MEDLINE