Assessment of airborne particles and bioaerosols concentrations in a waste recycling environment in Brazil.

Autor: Wikuats CFH; Federal University of Technology-Parana, 3131 Pioneiros Avenue, Londrina, PR, 86036-370, Brazil. carolinewikuats@alunos.utfpr.edu.br., Duarte EH; Federal University of Technology-Parana, 3131 Pioneiros Avenue, Londrina, PR, 86036-370, Brazil., Prates KVMC; Federal University of Technology-Parana, 3131 Pioneiros Avenue, Londrina, PR, 86036-370, Brazil., Janiaski LLL; Federal University of Technology-Parana, 3131 Pioneiros Avenue, Londrina, PR, 86036-370, Brazil.; Brandon University, 270 18th Street, Brandon, MB, R7A 6A9, Canada., de Oliveira Gabriel B; Federal University of Technology-Parana, 3131 Pioneiros Avenue, Londrina, PR, 86036-370, Brazil., da Cunha Molina A; Federal University of Technology-Parana, 3131 Pioneiros Avenue, Londrina, PR, 86036-370, Brazil., Martins LD; Federal University of Technology-Parana, 3131 Pioneiros Avenue, Londrina, PR, 86036-370, Brazil.
Jazyk: angličtina
Zdroj: Scientific reports [Sci Rep] 2020 Sep 09; Vol. 10 (1), pp. 14812. Date of Electronic Publication: 2020 Sep 09.
DOI: 10.1038/s41598-020-71787-0
Abstrakt: This study aims to assess the concentrations of size-fractioned particle mass (PM 1.0 , PM 2.5 , PM 4.0 , PM 10 ) and number (PNC 0.3 , PNC 0.5 , PNC 1.0 , PNC 2.5 ), bacteria, and fungi in a Materials Recycling Facility (MRF) in Brazil. The measurements were performed inside the waste processing shed (P1) and in the outdoor environment (P2) during working days in winter and spring of 2017, and summer of 2019. A total of 2,400 min of PM, 1,440 min of PNC, and 216 samples of bioaerosols were collected in the morning and afternoon. P1 has the strongest air contamination with mean values of 475.5 ± 563.7 µg m -3 for PM 10 , 58.6 ± 36.0 cm -3 for PNC 0.3 , 1,088.8 ± 825.2 colony-forming units per cubic meter (CFU m -3 ) for bacteria, and 2,738.3 ± 1,381.3 CFU m -3 for fungi. The indoor/outdoor ratios indicated the large influence of indoor sources due to the activities performed inside P1 that promote the generation and resuspension of pollutants. Gram-positive bacteria dominated with 58.6% of indoor samples. Overall, our results show a critical indoor air quality situation in a Brazilian MRF, which may cause several health risks for waste pickers. Finally, we call attention to the lack of occupational exposure limits for bioaerosols in industrial workplaces and mainly in MRFs.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje