Dual-Hormone Closed-Loop System Using a Liquid Stable Glucagon Formulation Versus Insulin-Only Closed-Loop System Compared With a Predictive Low Glucose Suspend System: An Open-Label, Outpatient, Single-Center, Crossover, Randomized Controlled Trial.

Autor: Wilson LM; Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR wilsolea@ohsu.edu., Jacobs PG; Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR., Ramsey KL; Oregon Clinical and Translational Research Institute Biostatistics and Design Program, Oregon Health & Science University & Portland State University School of Public Health, Portland, OR., Resalat N; Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR., Reddy R; Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR., Branigan D; Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR., Leitschuh J; Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR., Gabo V; Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR., Guillot F; Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR., Senf B; Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR., El Youssef J; Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR.; Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR., Steineck IIK; Steno Diabetes Center Copenhagen, Gentofte, Denmark., Tyler NS; Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR., Castle JR; Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR.
Jazyk: angličtina
Zdroj: Diabetes care [Diabetes Care] 2020 Nov; Vol. 43 (11), pp. 2721-2729. Date of Electronic Publication: 2020 Sep 09.
DOI: 10.2337/dc19-2267
Abstrakt: Objective: To assess the efficacy and feasibility of a dual-hormone (DH) closed-loop system with insulin and a novel liquid stable glucagon formulation compared with an insulin-only closed-loop system and a predictive low glucose suspend (PLGS) system.
Research Design and Methods: In a 76-h, randomized, crossover, outpatient study, 23 participants with type 1 diabetes used three modes of the Oregon Artificial Pancreas system: 1 ) dual-hormone (DH) closed-loop control, 2 ) insulin-only single-hormone (SH) closed-loop control, and 3 ) PLGS system. The primary end point was percentage time in hypoglycemia (<70 mg/dL) from the start of in-clinic aerobic exercise (45 min at 60% VO 2max ) to 4 h after.
Results: DH reduced hypoglycemia compared with SH during and after exercise (DH 0.0% [interquartile range 0.0-4.2], SH 8.3% [0.0-12.5], P = 0.025). There was an increased time in hyperglycemia (>180 mg/dL) during and after exercise for DH versus SH (20.8% DH vs. 6.3% SH, P = 0.038). Mean glucose during the entire study duration was DH, 159.2; SH, 151.6; and PLGS, 163.6 mg/dL. Across the entire study duration, DH resulted in 7.5% more time in target range (70-180 mg/dL) compared with the PLGS system (71.0% vs. 63.4%, P = 0.044). For the entire study duration, DH had 28.2% time in hyperglycemia vs. 25.1% for SH ( P = 0.044) and 34.7% for PLGS ( P = 0.140). Four participants experienced nausea related to glucagon, leading three to withdraw from the study.
Conclusions: The glucagon formulation demonstrated feasibility in a closed-loop system. The DH system reduced hypoglycemia during and after exercise, with some increase in hyperglycemia.
(© 2020 by the American Diabetes Association.)
Databáze: MEDLINE