A multicentre analysis of the outcome of arteriovenous fistula in maintenance haemodialysis.

Autor: Jothi S; Madras Medical Mission Hospital, Chetpet, Chennai, India., Kg H; St.Gregorios Hospital Parumala, Thiruvalla, India., Lesley N; Madras Medical Mission Hospital, Chetpet, Chennai, India., Vijayan M; Madras Medical Mission Hospital, Chetpet, Chennai, India., Haridas Anupama S; Madras Medical Mission Hospital, Chetpet, Chennai, India., Mathew M; Madras Medical Mission Hospital, Chetpet, Chennai, India.; Pondicherry Institute of Medical Sciences, Kalapet, Puduchery, India., Parthasarathy R; Madras Medical Mission Hospital, Chetpet, Chennai, India., Sundarajan S; Madras Medical Mission Hospital, Chetpet, Chennai, India., P N; Madras Medical Mission Hospital, Chetpet, Chennai, India., Kumaraswamy L; Tanker Foundation, Chennai, India., Abraham G; Madras Medical Mission Hospital, Chetpet, Chennai, India.; Pondicherry Institute of Medical Sciences, Kalapet, Puduchery, India.
Jazyk: angličtina
Zdroj: Seminars in dialysis [Semin Dial] 2020 Sep; Vol. 33 (5), pp. 388-393. Date of Electronic Publication: 2020 Aug 21.
DOI: 10.1111/sdi.12907
Abstrakt: Introduction: Arteriovenous fistulas (AVF) are the preferred choice for vascular access in hemodialysis. We aim to identify factors that may contribute to AVF failure.
Methods: Data regarding AVF survival were collected from 441 patients. All AVFs were either radial or brachial, of the end-to-side variety. Parameters studied were age, gender, diabetes mellitus, hypertension prior to end-stage kidney disease (ESKD), site of fistula, blood flow rate, venous pressure, dialysis vintage and frequency, needle gauge used during dialysis, year of fistula creation, and details of fistula failure.
Findings: The 6-month, 1-year and 2-year AVF survival rates were 98.41%, 95.01%, and 89.57%. Failure rates were 17.2%, 5.5%, 26.8%, and 14.4% for dominant radial, non-dominant radial, dominant brachial and non-dominant brachial respectively (P < 0.001). Using a larger needle size had better AVF survival rate (P < 0.05). All other factors had no significant correlation with AVF failure.
Conclusion: There were no statistically significant differences in AVF patency with respect to gender, age, blood flow rate, presence of diabetes mellitus or systemic hypertension. A distally placed AVF in the nondominant arm had the best survival rate. Using a larger needle size, specifically 15G during dialysis, was associated with lowest AVF failure.
(© 2020 Wiley Periodicals LLC.)
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje