Local damage detection by nonlinear coda wave interferometry combined with time reversal.

Autor: Smagin N; Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520 - IEMN, LIA LICS/LEMAC, F-59000 Lille, France., Trifonov A; Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520 - IEMN, LIA LICS/LEMAC, F-59000 Lille, France., Bou Matar O; Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520 - IEMN, LIA LICS/LEMAC, F-59000 Lille, France., Aleshin VV; Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520 - IEMN, LIA LICS/LEMAC, F-59000 Lille, France; Tomsk State University, 634050 Tomsk, Russia. Electronic address: vladislav.aleshin@univ-lille.fr.
Jazyk: angličtina
Zdroj: Ultrasonics [Ultrasonics] 2020 Dec; Vol. 108, pp. 106226. Date of Electronic Publication: 2020 Jul 15.
DOI: 10.1016/j.ultras.2020.106226
Abstrakt: Coda wave interferometry (CWI) is a sensitive ultrasound method for the detection of weak and local changes in complex inhomogeneous media. In a nonlinear modification of the method discussed here, a high-frequency probe coda is compared to its replica obtained in the presence of low-frequency pumping. If, after the filtering-out of low frequencies, the coda signals are different, this is attributed to nonlinear pump-probe interaction induced by contact acoustical nonlinearity in the damaged zone. Actually, the CWI methods are used for global inspection of complex media, such as for example, concrete structures. In this work, a step forward is made; it consists in combining the CWI with the time-reversal (TR) technique in order to allow one to focus the pump wave on a selected area in the structure and to detect and localize a flaw. Time-reverse pump is possible only in pulsed mode due to the spatio-temporal wave compression. By this reason, the particularities of coda wave mixing in conventionally used continuous and pulsed pump mode are considered. It has been experimentally observed that an aftereffect of a pulsed pump provides a nonlinear interaction between pump and probe waves of a sufficient overall level for defect detection with TR. Finally, it was shown that a TR focusing even with the minimal available quality i.e., with only one transducer produces a sufficient contrast allowing to distinguish intact and damaged zones with nonlinear CWI.
Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2020 Elsevier B.V. All rights reserved.)
Databáze: MEDLINE