Feasibility of Multiparametric Positron Emission Tomography/Magnetic Resonance Imaging as a One-Stop Shop for Radiation Therapy Planning for Patients with Head and Neck Cancer.
Autor: | Olin AB; Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark. Electronic address: anders.olin@regionh.dk., Hansen AE; Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark; Faculty of Health and Medical Science, University of Copenhagen, Copenhagen, Denmark; Department of Radiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Rasmussen JH; Department of Otorhinolaryngology, Head & Neck Surgery, and Audiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Ladefoged CN; Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Berthelsen AK; Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Håkansson K; Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Vogelius IR; Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Specht L; Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Gothelf AB; Department of Oncology, Section of Radiotherapy, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark., Kjaer A; Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark; Cluster for Molecular Imaging, University of Copenhagen, Copenhagen, Denmark., Fischer BM; Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark; PET Centre, School of Biomedical Engineering and Imaging Sciences, Kings College London, UK., Andersen FL; Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark. |
---|---|
Jazyk: | angličtina |
Zdroj: | International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2020 Dec 01; Vol. 108 (5), pp. 1329-1338. Date of Electronic Publication: 2020 Jul 16. |
DOI: | 10.1016/j.ijrobp.2020.07.024 |
Abstrakt: | Purpose: Multiparametric positron emission tomography (PET)/magnetic resonance imaging (MRI) as a one-stop shop for radiation therapy (RT) planning has great potential but is technically challenging. We studied the feasibility of performing multiparametric PET/MRI of patients with head and neck cancer (HNC) in RT treatment position. As a step toward planning RT based solely on PET/MRI, a deep learning approach was employed to generate synthetic computed tomography (sCT) from MRI. This was subsequently evaluated for dose calculation and PET attenuation correction (AC). Methods and Materials: Eleven patients, including 3 pilot patients referred for RT of HNC, underwent PET/MRI in treatment position after a routine fluorodeoxyglucose-PET/CT planning scan. The PET/MRI scan protocol included multiparametric imaging. A convolutional neural network was trained in a leave-one-out process to predict sCT from the Dixon MRI. The clinical CT-based dose plans were recalculated on sCT, and the plans were compared in terms of relative differences in mean, maximum, near-maximum, and near-minimum absorbed doses for different volumes of interest. Comparisons between PET with sCT-based AC and PET with CT-based AC were assessed based on the relative differences in mean and maximum standardized uptake values (SUV Results: All 11 patients underwent PET/MRI in RT treatment position. Apart from the 3 pilots, full multiparametric imaging was completed in 45 minutes for 7 out of 8 patients. One patient terminated the examination after 30 minutes. With the exception of 1 patient with an inserted tracheostomy tube, all dosimetric parameters of the sCT-based dose plans were within ±1% of the CT-based dose plans. For PET, the mean difference was 0.4 ± 1.2% for SUV Conclusions: Performing multiparametric PET/MRI of patients with HNC in RT treatment position was clinically feasible. The sCT generation resulted in AC of PET and dose calculations sufficiently accurate for clinical use. These results are an important step toward using multiparametric PET/MRI as a one-stop shop for personalized RT planning. (Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |