Permanent Compared With Absorbable Suture for Vaginal Mesh Fixation During Total Hysterectomy and Sacrocolpopexy: A Randomized Controlled Trial.

Autor: Matthews CA; Department of Urology, Wake Forest Baptist Health, Winston Salem, and the Department of Obstetrics and Gynecology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina; Augusta University, Augusta, Georgia; Northwestern Feinberg School of Medicine, Chicago, Illinois; and Atrium Health, Charlotte, North Carolina., Geller EJ, Henley BR, Kenton K, Myers EM, Dieter AA, Parnell B, Lewicky-Gaupp C, Mueller MG, Wu JM
Jazyk: angličtina
Zdroj: Obstetrics and gynecology [Obstet Gynecol] 2020 Aug; Vol. 136 (2), pp. 355-364.
DOI: 10.1097/AOG.0000000000003884
Abstrakt: Objective: To compare mesh and permanent suture exposure rates in the first year after minimally invasive total hysterectomy and sacrocolpopexy with a light-weight polypropylene mesh using permanent or delayed absorbable sutures.
Methods: Across five centers in the United States, women were randomized to permanent or delayed absorbable suture for vaginal attachment of a Y-mesh during hysterectomy and sacrocolpopexy for stage II prolapse and worse. The primary outcome was mesh or permanent suture exposure in the first year after surgery. The secondary outcome was to compare a composite measure for success defined as leading edge of prolapse not beyond the hymen and apex not descended more than one third vaginal length, and no subjective bulge and no prolapse retreatment. Patients completed a pelvic examination including the pelvic organ prolapse quantification system and questionnaires at baseline, 6 weeks and 1 year postsurgery. A sample size of 80 per group was planned to compare the rate of mesh or permanent suture exposure in the permanent compared with delayed absorbable groups.
Results: From April 2015 to May 2019, 204 patients (n=102 permanent; n=102 delayed absorbable) were randomized. One hundred ninety-eight women had follow-up data, with 182 (93%) completing 1-year follow-up: 95 of 99 (96%) permanent, 87 of 101 (86%) delayed absorbable. The total rate of mesh or permanent suture exposure was 12 of 198 (6.1%): 5.1% for permanent compared with 7.0% for delayed absorbable (risk ratio 0.73, 95% CI 0.24-2.22). The majority (9/12) were asymptomatic. Composite success was 93% for permanent compared with 95% for delayed absorbable suture, P=.43). Six (3.0%) women had a serious adverse event.
Conclusion: Suture type used for vaginal graft attachment did not influence mesh or permanent suture exposure rates.
Funding Source: Boston Scientific Corporation.
Clinical Trial Registration: ClinicalTrials.gov, NCT02277925.