Assessment of the Change in Color of Maxillofacial Silicone after Curing Using a Mobile Phone Colorimeter Application.

Autor: Nimonkar SV; Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Medical Sciences, Wardha, Maharashtra, India, Phone: +91 8830977678, e-mail: snimonkar@gmail.com., Sathe S; Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Medical Sciences, Wardha, Maharashtra, India., Belkhode VM; Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Medical Sciences, Wardha, Maharashtra, India., Pisulkar S; Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Medical Sciences, Wardha, Maharashtra, India., Godbole S; Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Medical Sciences, Wardha, Maharashtra, India., Nimonkar PV; Trauma Care Center, Government Medical College, Nagpur, Maharashtra, India.
Jazyk: angličtina
Zdroj: The journal of contemporary dental practice [J Contemp Dent Pract] 2020 Apr 01; Vol. 21 (4), pp. 458-462. Date of Electronic Publication: 2020 Apr 01.
Abstrakt: Aim: To evaluate the change in color of the maxillofacial silicone after curing using a mobile phone colorimeter application.
Materials and Methods: A two-piece metal mold was fabricated. Twenty five samples were made using M511, maxillofacial silicone. A jig was prepared to hold the mobile phone at a fix distance from the samples. The color was measured for each sample in terms of HSV (hue, saturation, value) with the mobile phone colorimeter application after manipulation and after polymerization of the samples. Data were statistically analyzed using the Student's paired t test and the software used in the analysis was SPSS 22.0 version.
Results: The mean difference of hue was 1.32 ± 2.71, with p value 0.053. Mean differences in saturation was 0.72 ± 2.01, with p value 0.066. Mean differences in value were 2.16 ± 3.11, with a p value 0.002. The measure of value showed statistically significant differences ( p < 0.05).
Conclusion: There was a significant change in the value of the color of the maxillofacial silicone after polymerization.
Clinical Significance: Increasing the value of the color by 2-3% at the time of manipulation of the maxillofacial silicone with the use of a mobile phone colorimeter application can help the clinician to reproduce the same color in the final prosthesis after curing to achieve a predictable esthetic outcome for a facial prosthesis.