Diagnostic accuracy of positron emission tomography/computed tomography-driven biopsy for the diagnosis of lymphoma.
Autor: | Broccoli A; Institute of Hematology 'L. e A. Seràgnoli', University of Bologna, via Massarenti 9, 40138, Bologna, Italy., Nanni C; Nuclear Medicine, Medicina Nucleare Metropolitana, Sant'Orsola-Malpighi Hospital, University of Bologna, via Massarenti 9, 40138, Bologna, Italy., Cappelli A; Radiology Unit, Sant'Orsola-Malpighi Hospital, via Massarenti 9, 40138, Bologna, Italy., Bacci F; Haematopathology Unit, Sant'Orsola-Malpighi Hospital, via Massarenti 9, 40138, Bologna, Italy., Gasbarrini A; Oncological and Degenerative Spine Surgery, Institute of Orthopaedics 'Rizzoli', via Pupilli 1, 40136, Bologna, Italy., Tabacchi E; Nuclear Medicine, Medicina Nucleare Metropolitana, Sant'Orsola-Malpighi Hospital, University of Bologna, via Massarenti 9, 40138, Bologna, Italy., Piovani C; Oncological and Degenerative Spine Surgery, Institute of Orthopaedics 'Rizzoli', via Pupilli 1, 40136, Bologna, Italy., Argnani L; Institute of Hematology 'L. e A. Seràgnoli', University of Bologna, via Massarenti 9, 40138, Bologna, Italy., Ghermandi R; Oncological and Degenerative Spine Surgery, Institute of Orthopaedics 'Rizzoli', via Pupilli 1, 40136, Bologna, Italy., Sabattini E; Haematopathology Unit, Sant'Orsola-Malpighi Hospital, via Massarenti 9, 40138, Bologna, Italy., Golfieri R; Radiology Unit, Sant'Orsola-Malpighi Hospital, via Massarenti 9, 40138, Bologna, Italy., Fanti S; Nuclear Medicine, Medicina Nucleare Metropolitana, Sant'Orsola-Malpighi Hospital, University of Bologna, via Massarenti 9, 40138, Bologna, Italy., Zinzani PL; Institute of Hematology 'L. e A. Seràgnoli', University of Bologna, via Massarenti 9, 40138, Bologna, Italy. pierluigi.zinzani@unibo.it. |
---|---|
Jazyk: | angličtina |
Zdroj: | European journal of nuclear medicine and molecular imaging [Eur J Nucl Med Mol Imaging] 2020 Dec; Vol. 47 (13), pp. 3058-3065. Date of Electronic Publication: 2020 Jun 15. |
DOI: | 10.1007/s00259-020-04913-9 |
Abstrakt: | Introduction: Biopsy of affected tissue is required for lymphoma diagnosis and to plan treatment. Open incisional biopsy is traditionally the method of choice. Nevertheless, it requires hospitalization, availability of an operating room, and sometimes general anesthesia, and it is associated with several drawbacks. Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) can be potentially used to drive biopsy to the most metabolically active area within a lymph node or extranodal masses. Methods: A study of diagnostic accuracy was conducted to assess the performance of a PET-driven needle biopsy in patients with suspect active lymphoma. Results: Overall, 99 procedures have been performed: three (3.0%) were interrupted because of pain but were successfully repeated in two cases. Median SUVmax of target lesions was 10.7. In 84/96 cases, the tissue was considered adequate to formulate a diagnosis (diagnostic yield of 87.5%) and to guide the following clinical decision. The target specimen was a lymph node in 60 cases and an extranodal site in 36. No serious adverse events occurred. The sensitivity of this procedure was 96%, with a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 75%. Conclusion: Patients can benefit from a minimally invasive procedure which allows a timely and accurate diagnosis of lymphoma at onset or relapse. |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |