Thoracic Pedicle Morphometry of Dry Vertebral Columns in Relation to Trans-Pedicular Fixation: A Cross-Sectional Study From Central India.
Autor: | Verma V; Orthopaedics, All India Institute of Medical Sciences, Bhopal, IND., Santoshi JA; Orthopaedics, All India Institute of Medical Sciences, Bhopal, IND., Jain V; Orthopaedics, All India Institute of Medical Sciences, Bhopal, IND., Patel M; Anatomy, All India Institute of Medical Sciences, Bhopal, IND., Dwivedi M; Orthopaedics, All India Institute of Medical Sciences, Bhopal, IND., Nagar M; Orthopaedics, All India Institute of Medical Sciences, Bhopal, IND., Selvanayagam R; Orthopaedics, All India Institute of Medical Sciences, Bhopal, IND., Pal D; Orthopaedics, All India Institute of Medical Sciences, Bhopal, IND. |
---|---|
Jazyk: | angličtina |
Zdroj: | Cureus [Cureus] 2020 May 16; Vol. 12 (5), pp. e8148. Date of Electronic Publication: 2020 May 16. |
DOI: | 10.7759/cureus.8148 |
Abstrakt: | Introduction Trans-pedicular screw fixation is one of the main modalities of spinal instrumentation today. It is particularly challenging in the thoracic spine due to the narrow pedicle dimensions especially in the upper and mid-thoracic levels. We aimed to study the anatomical variations like pedicle dimensions and angulation in transverse and sagittal planes. Material and methods We conducted an anatomical investigation on 20 dry vertebral columns (14 male and six female), from T1 to T12 levels. The measurements included pedicle width, height, and transverse and sagittal angles of the pedicle. Numerical variables were summarized using mean and standard deviation. Results T12 vertebra was found to have the widest pedicle width (mean 7.89 ± 0.70 mm) and the widest pedicle height (mean 15.45±0.78 mm) while T5 vertebra (mean 3.65±0.40 mm) had the narrowest pedicle width. T1 vertebra had the maximum transverse angle of the pedicle (mean 30.37±2.56 degree); whereas, T2 vertebra had the maximum sagittal angle (mean 19.22±2.24 degree). Conclusion We have reported detailed pedicle measurements including their angulation for the thoracic spine in dry vertebral columns of central India. The pedicles are directed more medially from T1 to T10 levels and are almost neutral at T11 and T12 levels. These findings would not only be of immense help to the spinal surgeons but also help in designing implants and instrumentations specific for the thoracic spine for the central Indian population as well as aiding surgeons to perform more precise and, therefore, safe surgical procedures. Competing Interests: The authors have declared that no competing interests exist. (Copyright © 2020, Verma et al.) |
Databáze: | MEDLINE |
Externí odkaz: |