Autor: |
Adams HJA; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands., Kwee TC; Department of Radiology, Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, PO Box 30.001, 9700 RB Groningen, The Netherlands., Yakar D; Department of Radiology, Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, PO Box 30.001, 9700 RB Groningen, The Netherlands., Hope MD; Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA.; Radiology Service, Veterans Affairs Medical Center, San Francisco, CA., Kwee RM; Department of Radiology, Zuyderland Medical Center, Heerlen/Sittard/Geleen, The Netherlands. |
Abstrakt: |
OBJECTIVE. The purpose of this article is to systematically review and meta-analyze the diagnostic accuracy of chest CT in detecting coronavirus disease (COVID-19). MATERIALS AND METHODS. MEDLINE was systematically searched for publications on the diagnostic performance of chest CT in detecting COVID-19. Methodologic quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Meta-analysis was performed using a bivariate random-effects model. RESULTS. Six studies were included, comprising 1431 patients. All six studies included patients at high risk of COVID-19, and five studies explicitly reported that they included only symptomatic patients. Mean prevalence of COVID-19 was 47.9% (range, 27.6-85.4%). High or potential risk of bias was present throughout all QUADAS-2 domains in all six studies. Sensitivity ranged from 92.9% to 97.0%, and specificity ranged from 25.0% to 71.9%, with pooled estimates of 94.6% (95% CI, 91.9-96.4%) and 46.0% (95% CI, 31.9-60.7%), respectively. The included studies were statistically homogeneous in their estimates of sensitivity ( p = 0.578) and statistically heterogeneous in their estimates of specificity ( p < 0.001). CONCLUSION. Diagnostic accuracy studies on chest CT in COVID-19 suffer from methodologic quality issues. Chest CT appears to have a relatively high sensitivity in symptomatic patients at high risk of COVID-19, but it cannot exclude COVID-19. Specificity is poor. These data, along with other local factors such as COVID-19 prevalence, available real-time reverse transcriptase-polymerase chain reaction tests, staff, hospital, and CT scanning capacity, can be useful to healthcare professionals and policy makers to decide on the utility of chest CT for COVID-19 detection in the hospital setting. |