The comparison of electromagnetic with virtual bronchoscopic navigation accuracy at hybrid operating room in patient with sternal wires.
Autor: | Fernandez RAS; Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, China., Yu PSY; Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, China., Chan JWY; Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, China., Lim K; Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, China., Lau RWH; Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, China., Ng CSH; Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, China. |
---|---|
Jazyk: | angličtina |
Zdroj: | AME case reports [AME Case Rep] 2020 Jan 20; Vol. 4, pp. 5. Date of Electronic Publication: 2020 Jan 20 (Print Publication: 2020). |
DOI: | 10.21037/acr.2019.12.04 |
Abstrakt: | We describe a case of a 63-year-old lady with an incidental small right upper lobe ground glass opacity (GGO) lesion, who had history of open-heart surgery with bypass grafts for coronary artery disease. Video-assisted thoracic surgery (VATS) excisional biopsy with pre-operative localization was planned. Localization by percutaneous approach is challenging due to position of GGO shielded by both the scapular and ribs. Electromagnetic navigation accuracy may be affected by steel sternal wires but its effect has not been reported on literature. Both virtual and electromagnetic navigation bronchoscopy platforms were used with real-time cone-beam CT confirmation in the hybrid operating room to perform dye marking. Both navigation methods successfully marked the GGO for lung resection. Our case demonstrated that the accuracy of electromagnetic navigation in the presence of steel sternal wire is satisfactory for dye marking and the use of intra-operative cone-beam CT in hybrid operating room is invaluable for the success of navigational bronchoscopy. Competing Interests: Conflicts of Interest: CS Ng is a consultant for Medtronic, USA and Broncus. The other authors have no conflicts of interest to declare. (2020 AME Case Reports. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |