Advances in High-Resolution Radiation Detection Using 4H-SiC Epitaxial Layer Devices.
Autor: | Mandal KC; Department of Electrical Engineering, University of South Carolina, Columbia, SC 29208, USA., Kleppinger JW; Department of Electrical Engineering, University of South Carolina, Columbia, SC 29208, USA., Chaudhuri SK; Department of Electrical Engineering, University of South Carolina, Columbia, SC 29208, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | Micromachines [Micromachines (Basel)] 2020 Feb 28; Vol. 11 (3). Date of Electronic Publication: 2020 Feb 28. |
DOI: | 10.3390/mi11030254 |
Abstrakt: | Advances towards achieving the goal of miniature 4H-SiC based radiation detectors for harsh environment application have been studied extensively and reviewed in this article. The miniaturized devices were developed at the University of South Carolina (UofSC) on 8 × 8mm 4H-SiC epitaxial layer wafers with an active area of ≈11 mm 2 . The thicknesses of the actual epitaxial layers were either 20 or 50 µm. The article reviews the investigation of defect levels in 4H-SiC epilayers and radiation detection properties of Schottky barrier devices (SBDs) fabricated in our laboratories at UofSC. Our studies led to the development of miniature SBDs with superior quality radiation detectors with highest reported energy resolution for alpha particles. The primary findings of this article shed light on defect identification in 4H-SiC epilayers and their correlation with the radiation detection properties. |
Databáze: | MEDLINE |
Externí odkaz: |