Development of thin-film solid-phase microextraction coating and method for determination of artificial sweeteners in surface waters.
Autor: | Cárdenas-Soracá DM; Department of Instrumental Analysis, Faculty of Pharmacy, University of Concepcion, PO Box 160-C, Concepcion, Chile; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada., Singh V; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada., Nazdrajić E; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada., Vasiljević T; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada., Grandy JJ; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada., Pawliszyn J; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada. Electronic address: janusz@uwaterloo.ca. |
---|---|
Jazyk: | angličtina |
Zdroj: | Talanta [Talanta] 2020 May 01; Vol. 211, pp. 120714. Date of Electronic Publication: 2020 Jan 07. |
DOI: | 10.1016/j.talanta.2020.120714 |
Abstrakt: | A semi-automated and sensitive method was developed for simultaneous determination of the six most consumed artificial sweeteners (AS) in surface waters using thin-film solid-phase microextraction (TF-SPME) and high-performance liquid chromatography (HPLC). A triple quadrupole mass spectrometer and an electrospray ionization source (ESI-MS) run in negative ionization and multiple reaction monitoring modes were employed for instrumental analysis. The TF-SPME method was optimized for the extraction phase, sample pH, desorption solvent, extraction time, and desorption time. In-house-synthetized-hydrophilic-lipophilic balance weak anion exchange (HLB-WAX) particles imbedded within a polyacrylonitrile (PAN) binder were selected as the extraction phase for the thin-film coating due to their cost-effectiveness and enhanced sensitivity for artificial sweeteners. Suitable analytical parameters that include linearity (R 2 > 0.9914), recovery > 80%, inter, and intra-reproducibility less than 18% were obtained for the AS compounds studied. The developed method estimated limits of detection (LODs) ranging from 0.004 to 0.038 ng mL -1 The SPME method was successfully applied for the determination of ultra-trace levels of AS in water samples collected from Grand River (Ontario, Canada), downstream of three municipal wastewater treatment plants (WWTPs). Concentrations ranging from 0.03 to 20.3 ng mL -1 were found for the AS compounds studied. Competing Interests: Declaration of competing interest All authors declare they have no conflicts of interest. (Copyright © 2020 Elsevier B.V. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |