Use of Multiphase CT Protocols in 18 Countries: Appropriateness and Radiation Doses.

Autor: Rastogi S; MGH Webster Center for Quality and Safety, 2348Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA., Singh R; MGH Webster Center for Quality and Safety, 2348Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA., Borse R; MGH Webster Center for Quality and Safety, 2348Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA., Valkovic Zujic P; Department of Radiology, University Hospital Rijeka, Rijeka, Croatia., Segota D; Department of Medical Physics, University Hospital Rijeka, Rijeka, Croatia., Diklic A; Department of Medical Physics, University Hospital Rijeka, Rijeka, Croatia., Jurkovic S; Department of Medical Physics, University Hospital Rijeka, Rijeka, Croatia., Ali A; Hamad Medical Corporation, Doha, Qatar., Mohammed Kharita H; Hamad Medical Corporation, Doha, Qatar., Al-Naemi HM; Hamad Medical Corporation, Doha, Qatar., Alkalbani J; Department of Radiology, Royal Hospital, Muscat, Oman., Al-Rasbi A; Department of Radiology, Sultan Qaboos University Hospital, Muscat, Oman., Gershan V; Faculty of Natural Sciences and Mathematics, University SS Cyril and Methodius, Skopje, North Macedonia., Galic S; Medical Physics and Radiation Protection Office, University Clinical Hospital Mostar, Mostar, Bosnia and Herzegovina., Yusuf M; Department of Radiology, Aga Khan University Hospital, Karachi, Pakistan., Avramova-Cholakova S; Medical Physics Laboratory, University Hospital Acibadem City Clinic, Sofia, Bulgaria., Zulkipli IMBH; Raja Isteri Pengiran Anak Saleha Hospital, Bandar Seri Begawan, Brunei Darussalam., Shein N; Department of Radiology, Pun Hlaing Siloam Hospital, Yangon, Myanmar., Teferi S; Department of Radiology, Tikur Anbessa Specialized Hospital, Addis Abada, Ethiopia., Rehani MM; MGH Webster Center for Quality and Safety, 2348Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA., Vassileva J; International Atomic Energy Agency, Vienna, Austria., Kalra MK; MGH Webster Center for Quality and Safety, 2348Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
Jazyk: angličtina
Zdroj: Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes [Can Assoc Radiol J] 2021 Aug; Vol. 72 (3), pp. 381-387. Date of Electronic Publication: 2020 Jan 27.
DOI: 10.1177/0846537119888390
Abstrakt: Purpose: To assess the frequency, appropriateness, and radiation doses associated with multiphase computed tomography (CT) protocols for routine chest and abdomen-pelvis examinations in 18 countries.
Materials and Methods: In collaboration with the International Atomic Energy Agency, multi-institutional data on clinical indications, number of scan phases, scan parameters, and radiation dose descriptors (CT dose-index volume; dose-length product [DLP]) were collected for routine chest (n = 1706 patients) and abdomen-pelvis (n = 426 patients) CT from 18 institutions in Asia, Africa, and Europe. Two radiologists scored the need for each phase based on clinical indications (1 = not indicated, 2 = probably indicated, 3 = indicated). We surveyed 11 institutions for their practice regarding single-phase and multiphase CT examinations. Data were analyzed with the Student t test.
Results: Most institutions use multiphase protocols for routine chest (10/18 institutions) and routine abdomen-pelvis (10/11 institutions that supplied data for abdomen-pelvis) CT examinations. Most institutions (10/11) do not modify scan parameters between different scan phases. Respective total DLP for 1-, 2-, and 3-phase routine chest CT was 272, 518, and 820 mGy·cm, respectively. Corresponding values for 1- to 5-phase routine abdomen-pelvis CT were 400, 726, 1218, 1214, and 1458 mGy cm, respectively. For multiphase CT protocols, there were no differences in scan parameters and radiation doses between different phases for either chest or abdomen-pelvis CT ( P = 0.40-0.99). Multiphase CT examinations were unnecessary in 100% of routine chest CT and in 63% of routine abdomen-pelvis CT examinations.
Conclusions: Multiphase scan protocols for the routine chest and abdomen-pelvis CT examinations are unnecessary, and their use increases radiation dose.
Databáze: MEDLINE