Extraction of impacted third molar with preventive installation of titanium miniplate: Case report.
Autor: | Feniar JG; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil., Kawano H; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil., Vianna Camolesi GC; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil., Palmieri M; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil.; Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil., De Souza Sobral S; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil.; Department of Biophotonics Applied to Health and Sciences, University Nove de Julho, UNINOVE, São Paulo, Brazil., Duarte FL; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil., Barboni Maringoli MJ; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil., Bauer HC; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil., Jorge WA; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil.; Integrated Clinic, Department of Estomatology, São Paulo University, São Paulo, Brazil., Negreiros RM; Foundation for Scientific and Technological Development of Dentistry at University of São Paulo (FFO-USP), School of Dentistry, FOUSP, University of São Paulo, São Paulo, Brazil, Av Professor Lineu Prestes, 2227, Butantã, CEP:05508-000, São Paulo, SP, Brazil.; University Nove de Julho, UNINOVE, São Paulo, Brazil. |
---|---|
Jazyk: | angličtina |
Zdroj: | Annals of medicine and surgery (2012) [Ann Med Surg (Lond)] 2019 Nov 27; Vol. 49, pp. 33-36. Date of Electronic Publication: 2019 Nov 27 (Print Publication: 2020). |
DOI: | 10.1016/j.amsu.2019.11.014 |
Abstrakt: | Introduction: Even though is rarely, mandibular fracture after the extraction of third molars can occur in almost 1% of the procedures. Gender, age, position of third molar, tooth volume, bone fragility, systemic disorders, associated lesions, and degree of mandibular atrophy are factors that contribute to increase the incidence of fracture. The installation of the titanium miniplate during exodontia is an important tool to prevent the fracture. Presentation of Case: The objective of this study is to present a clinical case of extraction of inferior impacted third molar, in atrophic mandible, with posterior installation of titanium miniplate, to prevent mandibular fracture. Discussion and Conclusion: preventive installation of titanium miniplate was effective and indeed prevented the mandibular fracture. No trans-operative or immediate post-operative complications were observed. Post-operative follow-up was of three years, with no complications, showing the success of the procedure. Competing Interests: All authors declare that they have no conflict of interest regarding this article.and neighter financing relationship. (© 2019 The Authors. Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd.) |
Databáze: | MEDLINE |
Externí odkaz: |