The effect of prolonged steep head-down laparoscopy on the optical nerve sheath diameter.

Autor: Colombo R; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy. riccardo.colombo@asst-fbf-sacco.it., Agarossi A; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Borghi B; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Ottolina D; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Bergomi P; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Ballone E; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Minari C; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Della Porta V; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Menozzi E; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Figini S; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Fossali T; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy., Catena E; Department of Anesthesiology and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario - University of Milan, Via G.B. Grassi 74, 20157, Milan, Italy.
Jazyk: angličtina
Zdroj: Journal of clinical monitoring and computing [J Clin Monit Comput] 2020 Dec; Vol. 34 (6), pp. 1295-1302. Date of Electronic Publication: 2019 Nov 05.
DOI: 10.1007/s10877-019-00418-5
Abstrakt: Both the steep head-down position and pneumoperitoneum increase the intracranial pressure (ICP), and their combination for a prolonged period during laparoscopic radical prostatectomy (LRP) might influence the central nervous system homeostasis. Changes in optic nerve sheath diameter (ONSD) may reflect those in ICP. This study aims to quantify the change in ONSD in response to peritoneal CO 2 insufflation and steep Trendelenburg position during LRP. ONSD was measured by ultrasound in 20 patients undergoing LRP and ten awake healthy volunteers. In patients, ONSD was assessed at baseline immediately after induction of general anesthesia in supine position, 10 and 60 min from baseline in a 25° head-down position during pneumoperitoneum, and after deflation of pneumoperitoneum with the patient supine at 0° angle. ONSD in controls was assessed at baseline with the patient lying supine, after 10 and 60 min of 25° head-down position, and 10 min after repositioning at 0° angle. ONSD increased significantly in both patients and controls (p < 0.0001) without between-group differences. The mean increase was 10.3% (95% CI 7.7-12.9%) in patients versus 7.5% (95% CI 2.5-12.6%) in controls (p = 0.28), and didn't affect the time to recovery from anesthesia. In the studied patients, with a limited increase of end-tidal CO 2 and airway pressure, and low volume fluid infusion, the maximal ONSD was always below the cut-off value suspect for increased ICP. ONSD reflects the changes in hydrostatic pressure in response to steep Trendelenburg position, and its increase might be minimized by careful handling of general anesthesia.
Databáze: MEDLINE