Shear bond strength of composite resin to resin-modified glass ionomer cement using 2-hydroxyethyl methacrylate-based and 2-hydroxyethyl methacrylate-free adhesive system.
Autor: | Pandey SA; Department of Conservative Dentistry and Endodontics, MGV's KBH Dental College, Nashik, Maharashtra, India., Lokhande MT; Department of Conservative Dentistry and Endodontics, MGV's KBH Dental College, Nashik, Maharashtra, India., Gulve MN; Department of Conservative Dentistry and Endodontics, MGV's KBH Dental College, Nashik, Maharashtra, India., Kolhe SJ; Department of Conservative Dentistry and Endodontics, MGV's KBH Dental College, Nashik, Maharashtra, India., Aher GB; Department of Conservative Dentistry and Endodontics, MGV's KBH Dental College, Nashik, Maharashtra, India. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of conservative dentistry : JCD [J Conserv Dent] 2019 May-Jun; Vol. 22 (3), pp. 292-295. |
DOI: | 10.4103/JCD.JCD_456_18 |
Abstrakt: | Background: Sandwich technique combines the properties of both composite resin and glass ionomer cement to make the most of the physical and esthetic properties of each material. Bonding agents improve the wettability of GIC surface and improves the bond between composite resin and GIC. The aim of this study was to evaluate and compare shear bond strength of composite resin to resin modified glass ionomer cement using HEMA-based and HEMA-free adhesive systems. An in vitro study. Materials and Methods: Total 30 disc-shaped samples were prepared with resin modified glass ionomer cement (RMGIC). Samples were divided into three groups, each group containing 10 samples. Group I (n=10): Nano-hybrid composite resin (NHCR) was bonded to RMGIC without any adhesive system. Group II (n=10): NHCR was bonded to RMGIC using hydroxyethylmethacrylate (HEMA)-based adhesive system. Group III (n=10): NHCR was bonded to RMGIC using HEMA-free adhesive system. The shear bond strength was tested using Universal testing Machine and the results were calculated using one way ANOVA and Post-Hoc test. Results: Maximum shear bond strength was recorded in group III where HEMA-free adhesive used with a mean value of 6.13±1.859 MPa followed by group II where HEMA-based adhesive used with mean value of 4.38±1.533 MPa. The control group showed least shear bond strength. Conclusion: Application of HEMA-free adhesive (OptiBond All-In-One) resulted in greater shear bond strength between RMGIC and composite resin than HEMA-based adhesive (Single bond Universal Adhesive). Competing Interests: There are no conflicts of interest. |
Databáze: | MEDLINE |
Externí odkaz: |