Chromatographic determination of 12 dyes in meat products by HPLC-UV-DIODE array detection.

Autor: Iammarino M; National Reference Center for the Detection of Radioactivity in Feed and Foodstuff, Istituto Zooprofilattico Sperimentale della Puglia e della Basilicata, Via Manfredonia 20, 71121, Foggia, Italy., Mentana A; Department of the Sciences of Agriculture, Food and Environment, University of Foggia, Via Napoli, 25, 71122, Foggia, Italy., Centonze D; Department of the Sciences of Agriculture, Food and Environment, University of Foggia, Via Napoli, 25, 71122, Foggia, Italy., Palermo C; Department of the Sciences of Agriculture, Food and Environment, University of Foggia, Via Napoli, 25, 71122, Foggia, Italy., Mangiacotti M; National Reference Center for the Detection of Radioactivity in Feed and Foodstuff, Istituto Zooprofilattico Sperimentale della Puglia e della Basilicata, Via Manfredonia 20, 71121, Foggia, Italy., Chiaravalle AE; National Reference Center for the Detection of Radioactivity in Feed and Foodstuff, Istituto Zooprofilattico Sperimentale della Puglia e della Basilicata, Via Manfredonia 20, 71121, Foggia, Italy.
Jazyk: angličtina
Zdroj: MethodsX [MethodsX] 2019 Apr 22; Vol. 6, pp. 856-861. Date of Electronic Publication: 2019 Apr 22 (Print Publication: 2019).
DOI: 10.1016/j.mex.2019.04.018
Abstrakt: The use of food dyes in meat is regulated by the current European and non-European legislation, due to several food safety concerns. A reliable method for the quali-quantitative determination of 12 food dyes (Amaranth, Ponceau 4R, Carmine, Ponceau SX, Ponceau 3R, Allura Red AC, Carmoisine, Erythrosine, Sudan I, Sudan II, Sudan III and Sudan IV) in meat products, by high performance liquid chromatography coupled to UV diode array detection is presented. The extraction was accomplished by using acetonitrile, methanol, water, and ammonia, 50:40:9:1 (v/v/v/v) as the solvent and ultrasonic bath. The chromatographic separation was obtained with a C 18 RP column eluted by a gradient of acetate buffer/acetonitrile. Good analytical performances characterized this method (Table 1), in terms of selectivity, sensitivity, accuracy and ruggedness. Both method precision (CV% range: 6%-15%) and recovery percentages (range: 86%-105%) resulted in compliance with Decision 2002/657/EC, and the expanded measurement uncertainties, estimated by a bottom-up approach, were in the range 6%-20%. All these results demonstrated that the procedure can be applied successfully for confirmation analyses of commercial meat products. •12 food dyes were determined in meat by new HPLC/UV-DAD method.•The analytical method was fully validated for accurate confirmation analyses.•Method accuracy, sensitivity, selectivity and ruggedness resulted satisfactory.
Databáze: MEDLINE