Improving single-event proton CT by removing nuclear interaction events within the energy/range detector.

Autor: Volz L; Department of Biomedical Physics in Radiation Oncology, Deutsches Krebsfoschungszentrum (DKFZ), Heidelberg, Baden-Württemberg, Germany. Department of Physics and Astronomy, Heidelberg University, Heidelberg, Baden-Württemberg, Germany., Piersimoni P, Johnson RP, Bashkirov VA, Schulte RW, Seco J
Jazyk: angličtina
Zdroj: Physics in medicine and biology [Phys Med Biol] 2019 Aug 01; Vol. 64 (15), pp. 15NT01. Date of Electronic Publication: 2019 Aug 01.
DOI: 10.1088/1361-6560/ab2671
Abstrakt: Data filtering is crucial for accurate relative stopping power (RSP) reconstruction in proton CT (pCT). In this work, we assess different filters and their performance for the US pCT collaboration prototype pCT system in Monte Carlo (MC) simulations. The potential of using the recently proposed [Formula: see text]-E filter for removing nuclear interactions that occurred in the energy/range detector of the pCT system is investigated. Full pCT scans were acquired with the TOPAS MC simulated version of the prototype scanner that comprises two tracking detectors and a five stage energy/range detector. An ideal water cylinder and a water cylinder with five tissue inserts were investigated. Before image reconstruction, a [Formula: see text] WEPL filter was applied as the only filter, or in addition to filters acting on the energy deposit in each of the energy detector stages, as done currently with the prototype. The potential of the [Formula: see text]-E filter that was recently proposed for helium imaging was assessed. The results were compared to simulations for which nuclear interactions were disabled representing ground truth. The [Formula: see text] WEPL filter alone was not sufficient to filter out all nuclear interaction events and systematic fluctuations in the form of ring artifacts were present in the pCT reconstructed images. Applying energy filters currently used with the device prior to the [Formula: see text] WEPL filter only slightly improved the image quality. A [Formula: see text] WEPL filter improved the mean RSP accuracy, but could not fully remove the systematic fluctuations. The [Formula: see text]-E filter in addition to the current reconstruction procedure efficiently removed the systematic fluctuations and the achieved RSP accuracy closely matched the simulation without nuclear interactions. This study demonstrates the dependence of the accuracy of the usual [Formula: see text] WEPL filter on uncertainties arising within the energy detector. By enabling to remove such uncertainties, the [Formula: see text]-E method proved to yield some potential for improving the accuracy of pCT.
Databáze: MEDLINE