A Comparison of Stress Response between Insertion of Gastro-laryngeal Tube and Endotracheal Intubation in Patients Undergoing Upper Gastrointestinal Endoscopic Procedures for Endoscopic Retrograde Cholangiopancreatography.

Autor: Davis J; Department of Anesthesia and Critical Care, Command Hospital (Southern Command), Pune, Maharashtra, India., Sreevastava DK; Department of Anesthesia and Critical Care, Command Hospital (Southern Command), Pune, Maharashtra, India., Dwivedi D; Department of Anesthesia and Critical Care, Command Hospital (Southern Command), Pune, Maharashtra, India., Gadgi S; Department of Anesthesia and Critical Care, Command Hospital (Southern Command), Pune, Maharashtra, India., Sud S; Department of Anesthesia and Critical Care, Command Hospital (Southern Command), Pune, Maharashtra, India., Dudeja P; Department of Community Medicine, Armed Forces Medical College, Pune, Maharashtra, India.
Jazyk: angličtina
Zdroj: Anesthesia, essays and researches [Anesth Essays Res] 2019 Jan-Mar; Vol. 13 (1), pp. 13-18.
DOI: 10.4103/aer.AER_9_19
Abstrakt: Background: Complex gastrointestinal (GI) endoscopic procedures like endoscopic retrograde cholangiopancreatography (ERCP) require deep sedation or general anesthesia. Comorbidities with the poor physiological condition warrant endotracheal intubation to prevent hypoxia and aspiration. The gastro-laryngeal tube (GLT), a new supraglottic airway device with a separate channel for endoscope looks promising.
Aims: The aim of the study is to compare the stress response during insertion of GLT and endotracheal intubation (ETT) in patients undergoing upper GI endoscopic procedures like ERCP.
Subjects and Methods: This control versus comparison study comprised two groups with 30 patients each who underwent ETT and GLT insertion. The standard general anesthesia technique was used. In GLT group, the device was inserted without neuromuscular blocker. In ETT group, injection atracurium 0.5 mg/kg intravenous was administered as muscle relaxant for aiding endotracheal intubation. Hemodynamic parameters and time taken for the insertion of GLT/ETT were recorded.
Statistical Analysis: Data were analyzed using SPSS version 20. Student's t -test was used to compare quantitative data between the groups. ANOVA test was applied for intragroup comparisons between GLT and ETT groups. Categorical variables were analyzed using the Chi-square test.
Results: Heart rate and mean arterial pressure increased from baseline in ETT group, following laryngoscopy and endotracheal intubation as well as with GLT insertion. However, the stress response caused by endotracheal intubation was significantly greater than that caused by GLT insertion.
Conclusion: GLT as an airway device is a safe alternative with decreased stress response compared to endotracheal intubation for upper GI endoscopy procedures.
Competing Interests: There are no conflicts of interest.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje