Evaluation of multiple laboratory performance and variability in analysis of recreational freshwaters by a rapid Escherichia coli qPCR method (Draft Method C).
Autor: | Aw TG; Department of Global Environmental Health Sciences, School of Public Health and Tropical Medicine, Tulane University, 1440 Canal Street, Suite 2100, New Orleans, LA, 70112, USA., Sivaganesan M; U.S. Environmental Protection Agency, National Risk Management Research Laboratory, 26 W. M.L. King Dr, Cincinnati, OH, 45268, USA., Briggs S; Water Resources Division, Michigan Department of Environmental Quality, P. O. Box 30458, 525 West Allegan Street, Lansing, MI, 48909, USA., Dreelin E; Center for Water Sciences, Michigan State University, 1405 South Harrison Road, East Lansing, MI, 48823, USA., Aslan A; Georgia Southern University, Department of Environmental Health Sciences, 501 Forest Drive, Statesboro, GA, 30458, USA., Dorevitch S; University of Illinois at Chicago, School of Public Health, 2121 W. Taylor Street, Chicago, IL, 60612, USA., Shrestha A; University of Illinois at Chicago, School of Public Health, 2121 W. Taylor Street, Chicago, IL, 60612, USA., Isaacs N; U.S. Geological Survey, Upper Midwest Water Science Center, 6520 Mercantile Way, Ste 5, Lansing, MI, 48911, USA., Kinzelman J; City of Racine Public Health Department, 730 Washington Ave, Racine, WI, 53403, USA., Kleinheinz G; University of Wisconsin-Oshkosh, Environmental Research Laboratory, 800 Algoma Boulevard, Oshkosh, WI, 54901, USA., Noble R; Institute of Marine Sciences, University of North Carolina at Chapel Hill, 3431 Arendell Street, Morehead City, NC, 28557, USA., Rediske R; Annis Water Resources Institute, Lake Michigan Center, 740 W. Shoreline Dr, Muskegon, MI, 49441, USA., Scull B; Annis Water Resources Institute, Lake Michigan Center, 740 W. Shoreline Dr, Muskegon, MI, 49441, USA., Rosenberg S; Oakland County Health Division Laboratory, 1200 N. Telegraph, Pontiac, MI, 48341, USA., Weberman B; Oakland County Health Division Laboratory, 1200 N. Telegraph, Pontiac, MI, 48341, USA., Sivy T; Saginaw Valley State University, Department of Chemistry, 7400 Bay Road, University Center, MI, 48710, USA., Southwell B; Lake Superior State University, Environmental Analysis Laboratory, 650 W. Easterday Ave, Sault Ste Marie, MI, 49783, USA., Siefring S; U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, 26 W. M.L. King Dr, Cincinnati, OH, 45268, USA., Oshima K; U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, 26 W. M.L. King Dr, Cincinnati, OH, 45268, USA., Haugland R; U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, 26 W. M.L. King Dr, Cincinnati, OH, 45268, USA. Electronic address: haugland.rich@epa.gov. |
---|---|
Jazyk: | angličtina |
Zdroj: | Water research [Water Res] 2019 Jun 01; Vol. 156, pp. 465-474. Date of Electronic Publication: 2019 Mar 16. |
DOI: | 10.1016/j.watres.2019.03.014 |
Abstrakt: | There is interest in the application of rapid quantitative polymerase chain reaction (qPCR) methods for recreational freshwater quality monitoring of the fecal indicator bacteria Escherichia coli (E. coli). In this study we determined the performance of 21 laboratories in meeting proposed, standardized data quality acceptance (QA) criteria and the variability of target gene copy estimates from these laboratories in analyses of 18 shared surface water samples by a draft qPCR method developed by the U.S. Environmental Protection Agency (EPA) for E. coli. The participating laboratories ranged from academic and government laboratories with more extensive qPCR experience to "new" water quality and public health laboratories with relatively little previous experience in most cases. Failures to meet QA criteria for the method were observed in 24% of the total 376 test sample analyses. Of these failures, 39% came from two of the "new" laboratories. Likely factors contributing to QA failures included deviations in recommended procedures for the storage and preparation of reference and control materials. A master standard curve calibration model was also found to give lower overall variability in log (Published by Elsevier Ltd.) |
Databáze: | MEDLINE |
Externí odkaz: |