Fricke xylenol glycine gel dosimeter for in vivo dosimetry at extended treatment distance.

Autor: Ebenezer Suman Babu S; Department of Radiotherapy, Christian Medical College, Vellore 632004, Tamil Nadu, India. Electronic address: emailstoebi@gmail.com., Mohamathu Rafic K; Department of Radiotherapy, Christian Medical College, Vellore 632004, Tamil Nadu, India., Timothy Peace BS; Department of Radiotherapy, Christian Medical College, Vellore 632004, Tamil Nadu, India., Jose Solomon Raj L; Department of Radiotherapy, Christian Medical College, Vellore 632004, Tamil Nadu, India., Paul Ravindran B; Department of Radiotherapy, Christian Medical College, Vellore 632004, Tamil Nadu, India.
Jazyk: angličtina
Zdroj: Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [Appl Radiat Isot] 2019 Mar; Vol. 145, pp. 217-222. Date of Electronic Publication: 2018 Sep 27.
DOI: 10.1016/j.apradiso.2018.09.028
Abstrakt: Fricke xylenol gelatin with glycine (FXG Gly ) as gel dosimeter was investigated for in vivo dosimetry at extended source-to-surface distance (eSSD) and validated with optically stimulated luminescence dosimeters (OSLD). FXG Gly dosimeter was calibrated with a low dose rate of 10 cGy/min at eSSD and evaluated using anthropomorphic phantom simulating the actual treatment scenario. The FXG Gly dosimeter was demonstrated as a suitable in vivo dosimeter for total body irradiation at eSSD with desirable dosimetric accuracy (± 2%) in comparison with OSLD or ionization chamber.
(Copyright © 2018 Elsevier Ltd. All rights reserved.)