Evaluation of 3 esterase tests for the diagnosis of subclinical mastitis at dry-off and freshening in dairy cattle.
Autor: | Kandeel SA; Department of Animal Medicine, Faculty of Veterinary Medicine, Benha University, Kalyobiya, 13637, Egypt; Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana 61802., Megahed AA; Department of Animal Medicine, Faculty of Veterinary Medicine, Benha University, Kalyobiya, 13637, Egypt; Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana 61802., Ebeid MH; Department of Animal Medicine, Faculty of Veterinary Medicine, Benha University, Kalyobiya, 13637, Egypt., Constable PD; Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana 61802. Electronic address: constabl@illinois.edu. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of dairy science [J Dairy Sci] 2019 Feb; Vol. 102 (2), pp. 1402-1416. Date of Electronic Publication: 2018 Dec 24. |
DOI: | 10.3168/jds.2017-14345 |
Abstrakt: | Subclinical mastitis (SCM) and intramammary infection (IMI) increase esterase activity in the glandular secretions of dairy cattle. Our objective was to evaluate the clinical performance of 3 commercially available esterase tests for diagnosing SCM and IMI. Foremilk samples were collected from 380 quarters (96 cows) at dry-off and from 329 quarters (83 cows) within 4 to 7 d after calving. Quarter somatic cell count (SCC) was measured using the reference method (DeLaval cell counter; De Laval International AB, Tumba, Sweden) with SCM defined as SCC >200,000 cells/mL. Bacterial culture of foremilk samples was used to diagnose IMI based on the growth of ≥100 cfu/mL. The SCC was estimated using 3 PortaSCC tests (PortaCheck, Moorestown, NJ) from the measured esterase activity and the California Mastitis Test (CMT). Clinical performance was evaluated using logistic regression to determine the area under the receiver operating characteristic curve (AUC) and identify test sensitivity (Se) and specificity (Sp) at the optimal cut-point for diagnosing SCM and IMI. Test agreement was also evaluated using the kappa coefficient (κ) and weighted κ. The PortaSCC color test was the best-performing PortaSCC test for diagnosing SCM at dry-off (AUC = 0.90, Se = 0.91, Sp = 0.81, κ = 0.71) and at freshening (AUC = 0.86, Se = 0.74, Sp = 0.95, κ = 0.72), at an optimal cut-point of ≥250,000 cells/mL but required 45 min to produce a result. For comparison, the CMT required 2 min to produce a result and a CMT score of trace or higher was superior to the PortaSCC color test for diagnosing SCM at dry-off (AUC = 0.95, Se = 0.95, Sp = 0.86, κ = 0.81) and freshening (AUC = 0.88, Se = 0.79, Sp = 0.95, κ = 0.76). The PortaSCC quick test was the best-performing PortaSCC test for diagnosing IMI at dry-off (AUC = 0.81, Se = 0.81, Sp = 0.78 κ = 0.40) and required 5 min to produce a result, whereas the PortaSCC color test was the best performing PortaSCC test for diagnosing IMI at freshening (AUC = 0.80, Se = 0.75, Sp = 0.79 κ = 0.38). For comparison, the CMT was inferior to the PortaSCC quick test for diagnosing IMI at dry-off (AUC = 0.73, Se = 0.76, Sp = 0.60, κ = 0.20) but was equivalent to the PortaSCC color test at freshening (AUC = 0.79, Se = 0.58, Sp = 0.93, κ = 0.50). The PortaSCC color and quick tests and CMT were considered good tests for diagnosing SCM and IMI because clinically useful tests typically have an AUC >0.80 and κ >0.6. Based on the test sensitivity, cost, and analysis time, there does not appear to be a persuasive reason to select the PortaSCC tests over the traditional CMT for diagnosing SCM and IMI. (Copyright © 2019 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |