Closed-loop cavitation control for focused ultrasound-mediated blood-brain barrier opening by long-circulating microbubbles.

Autor: Çavuşoğlu M; Center for MR-Research, University Children's Hospital Zurich, 8032 Zurich, Switzerland. Institute for Biomedical Engineering, ETH Zurich, 8091 Zurich, Switzerland. Information Technology and Electrical Engineering Department, Swiss Federal Institute of Technology, Institute for Biomedical Engineering, ETH Zurich, ETZ F 64.1, Gloriastrasse 35, 8092, Zurich, Switzerland. Author to whom any correspondence should be addressed., Zhang J, Ielacqua GD, Pellegrini G, Signorell RD, Papachristodoulou A, Brambilla D, Roth P, Weller M, Rudin M, Martin E, Leroux JC, Werner B
Jazyk: angličtina
Zdroj: Physics in medicine and biology [Phys Med Biol] 2019 Feb 11; Vol. 64 (4), pp. 045012. Date of Electronic Publication: 2019 Feb 11.
DOI: 10.1088/1361-6560/aafaa5
Abstrakt: Focused ultrasound (FUS) exposure in the presence of microbubbles (MBs) has been successfully used in the delivery of various sizes of therapeutic molecules across the blood-brain barrier (BBB). While acoustic pressure is correlated with the BBB opening size, real-time control of BBB opening to avoid vascular and neural damage is still a challenge. This arises mainly from the variability of FUS-MB interactions due to the variations of animal-specific metabolic environment and specific experimental setup. In this study, we demonstrate a closed-loop cavitation control framework to induce BBB opening for delivering large therapeutic molecules without causing macro tissue damages. To this end, we performed in mice long-term (5 min) cavitation monitoring facilitated by using long-circulating MBs. Monitoring the long-term temporal kinetics of the MBs under varying level of FUS pressure allowed to identify in situ, animal specific activity regimes forming pressure-dependent activity bands. This enables to determine the boundaries of each activity band (i.e. steady oscillation, transition, inertial cavitation) independent from the physical and physiological dynamics of the experiment. However, such a calibration approach is time consuming and to speed up characterization of the in situ, animal specific FUS-MB dynamics, we tested a novel method called 'pre-calibration' that closely reproduces the results of long-term monitoring but with a much shorter duration. Once the activity bands are determined from the pre-calibration method, an operation band can be selected around the desired cavitation dose. To drive cavitation in the selected operation band, we developed an adaptive, closed-loop controller that updates the acoustic pressure between each sonication based on measured cavitation dose. Finally, we quantitatively assessed the safety of different activity bands and validated the proposed methods and controller framework. The proposed framework serves to optimize the FUS pressure instantly to maintain the targeted cavitation level while improving safety control.
Databáze: MEDLINE