Evaluation of a Field-Deployable Insulated Isothermal Polymerase Chain Reaction Nucleic Acid Analyzer for Influenza A Virus Detection at Swine Exhibitions.

Autor: Lauterbach SE; 1 Department of Veterinary Preventive Medicine, The Ohio State University, Columbus, Ohio., Nelson SN; 1 Department of Veterinary Preventive Medicine, The Ohio State University, Columbus, Ohio., Nolting JM; 1 Department of Veterinary Preventive Medicine, The Ohio State University, Columbus, Ohio., Trujillo JD; 2 Diagnostic Medicine Pathobiology, Kansas State University, College of Veterinary Medicine, Manhattan, Kansas., Richt JA; 2 Diagnostic Medicine Pathobiology, Kansas State University, College of Veterinary Medicine, Manhattan, Kansas., Bowman AS; 1 Department of Veterinary Preventive Medicine, The Ohio State University, Columbus, Ohio.
Jazyk: angličtina
Zdroj: Vector borne and zoonotic diseases (Larchmont, N.Y.) [Vector Borne Zoonotic Dis] 2019 Mar; Vol. 19 (3), pp. 212-216. Date of Electronic Publication: 2018 Sep 05.
DOI: 10.1089/vbz.2018.2345
Abstrakt: Rapid detection of influenza A virus (IAV) at swine exhibitions, where zoonotic transmission has occurred, can allow exhibition officials to quickly implement mitigation strategies and reduce public health risk. While laboratory diagnostic methods using PCR exist, pen-side detection of IAV can reduce lag time between sample collection and results. Portable insulated isothermal PCR (RT-iiPCR) has been used for point-of-care pathogen detection in veterinary medicine. This study compared laboratory methods of real-time reverse transcription PCR (rRT-PCR) to RT-iiPCR to determine the potential effectiveness of RT-iiPCR for detection of IAV in swine in the field. Two methods of extraction (magnetic bead and spin-column) and the two PCR platforms were used in a crossover study design to detect IAV in nasal wipes of 150 individual swine from one exhibition. Magnetic bead extraction is considered the laboratory gold standard while spin-column purification is considered the field-deployable method. IAV RNA was detected in 17 samples using Mag/rRT-PCR (reference assay) and 16 samples using Mag/RT-iiPCR (Sensitivity-S 76.5%), whereas only 14 samples using Spin/rRT-PCR (S 88.2%) and 12 samples using Spin/RT-iiPCR (field method) (S 58.8%) were positive, demonstrating a reduction in detection of viral RNA using column purification. There is moderate agreement (Cohen's kappa = 0.6575) between Mag/rRT-PCR and Spin/RT-iiPCR. There is good agreement between both PCR assays when using the same method of extraction (Mag: Cohen's kappa = 0.8203, Spin: Cohen's kappa = 0.7642). RT-iiPCR requires testing of 10 more samples than the rRT-PCR to detect disease at the 95% confidence level in a population of 300 animals with a disease prevalence of 20%. In conclusion, although there is some reduction in sensitivity, RT-iiPCR used in conjunction with spin-column purification is an acceptable method of IAV in swine detection at exhibitions where it may help reduce lag time and allow for rapid control of an IAV outbreak.
Databáze: MEDLINE