Porous silicon-poly(ε-caprolactone) film composites: evaluation of drug release and degradation behavior.

Autor: Bodiford NK; Department of Chemistry and Biochemistry, Texas Christian University, Fort Worth, TX, 76129, USA., McInnes SJP; University of South Australia, GPO Box 2471, Adelaide, South Australia, 5001, Australia., Voelcker NH; Victorian Node of the Australian National Fabrication Facility, Melbourne Centre for Nanofabrication, 151 Wellington Road, Clayton, VIC, 3168, Australia.; Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia.; Commonwealth Scientific and Industrial Research Organisation (CSIRO), Clayton, VIC, 3168, Australia., Coffer JL; Department of Chemistry and Biochemistry, Texas Christian University, Fort Worth, TX, 76129, USA. j.coffer@tcu.edu.
Jazyk: angličtina
Zdroj: Biomedical microdevices [Biomed Microdevices] 2018 Aug 10; Vol. 20 (3), pp. 71. Date of Electronic Publication: 2018 Aug 10.
DOI: 10.1007/s10544-018-0313-5
Abstrakt: This work focuses on an evaluation of novel composites of porous silicon (pSi) with the biocompatible polymer ε-polycaprolactone (PCL) for drug delivery and tissue engineering applications. The degradation behavior of the composites in terms of their morphology along with the effect of pSi on polymer degradation was monitored. PSi particles loaded with the drug camptothecin (CPT) were physically embedded into PCL films formed from electrospun PCL fiber sheets. PSi/PCL composites revealed a release profile of CPT (monitored via fluorescence spectroscopy) in accordance with the Higuchi release model, with significantly lower burst release percentage compared to pSi microparticles alone. Degradation studies of the composites, using gravimetric analysis, differential scanning calorimetry (DSC), and field emission scanning electron microscopy (FESEM), carried out in phosphate-buffered saline (PBS) under simulated physiological conditions, indicated a modest mass loss (15%) over 5 weeks due to pSi dissolution and minor polymer hydrolysis. DSC results showed that, relative to PCL-only controls, pSi suppressed crystallization of the polymer film during PBS exposure. This suppression affects the evolution of surface morphology during this exposure that, in turn, influences the degradation behavior of the polymer. The implications of the above properties of these composites as a possible therapeutic device are discussed.
Databáze: MEDLINE