Size-strain separation in diffraction line profile analysis.

Autor: Scardi P; Department of Civil, Environmental and Mechanical Engineering, University of Trento, Trento, Italy., Ermrich M; Röntgenlabor Dr Ermrich, Am Kandelborn 7, D-64354 Reinheim, Germany., Fitch A; ESRF, 71 avenue des Martyrs, CS 40220, 38043 Grenoble Cedex, France., Huang EW; Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan., Jardin R; Bruker AXS GmbH, Oestliche Rheinbrueckenstrasse 49, 76187 Karlsruhe, Germany., Kuzel R; Department of Condensed Matter Physics, Charles University, Prague, Czech Republic., Leineweber A; Institute of Materials Science, TU Bergakademie Freiberg, D-09599 Freiberg, Germany., Mendoza Cuevas A; Archaeometry Laboratory, Havana's Historian Office, University San Geronimo de La Habana, Habana, Vieja, Cuba.; Multidisciplinary Laboratory, ICTP, I-34151 Trieste, Italy., Misture ST; Alfred University, Alfred, NY 14802, USA., Rebuffi L; Elettra-Sincrotrone Trieste, Trieste, Italy., Schimpf C; Institute of Materials Science, TU Bergakademie Freiberg, D-09599 Freiberg, Germany.
Jazyk: angličtina
Zdroj: Journal of applied crystallography [J Appl Crystallogr] 2018 May 29; Vol. 51 (Pt 3), pp. 831-843. Date of Electronic Publication: 2018 May 29 (Print Publication: 2018).
DOI: 10.1107/S1600576718005411
Abstrakt: Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size-strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensity values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.
Databáze: MEDLINE