The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up.
Autor: | Kieser DC; 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand., Ailabouni R; 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand., Kieser SCJ; 2 Department of Radiology, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand., Wyatt MC; 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand., Armour PC; 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand., Coates MH; 2 Department of Radiology, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand., Hooper GJ; 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand. |
---|---|
Jazyk: | angličtina |
Zdroj: | Hip international : the journal of clinical and experimental research on hip pathology and therapy [Hip Int] 2018 Nov; Vol. 28 (6), pp. 668-674. Date of Electronic Publication: 2018 May 21. |
DOI: | 10.1177/1120700018760817 |
Abstrakt: | Introduction: Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. Methods: This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Results: Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. Conclusions: The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening. |
Databáze: | MEDLINE |
Externí odkaz: |