Autor: Dondi M; Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health; IAEA, Vienna, Austria.. Electronic address: mauriziodondi@yahoo.it., Paez D; Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health; IAEA, Vienna, Austria., Torres L; Dirección de Investigaciones Clinicas, CENTIS; La Habana, Cuba., Marengo M; Azienda Ospedaliera S.Orsola-Malpighi; Bologna; Italy., Delaloye AB; CHUV, Lausanne, Switzerland., Solanki K; Addenbrooke's Hospital, Cambridge University Hospitals, UK., Van Zyl Ellmann A; Stellenbosch University and Tygerberg Hospital; Western Cape, South Africa., Lobato EE; Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health; IAEA, Vienna, Austria., Miller RN; Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health; IAEA, Vienna, Austria., Giammarile F; Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health; IAEA, Vienna, Austria., Pascual T; Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health; IAEA, Vienna, Austria.
Jazyk: angličtina
Zdroj: Seminars in nuclear medicine [Semin Nucl Med] 2018 May; Vol. 48 (3), pp. 299-306. Date of Electronic Publication: 2018 Feb 09.
DOI: 10.1053/j.semnuclmed.2017.12.001
Abstrakt: The International Atomic Energy Agency (IAEA) developed a comprehensive program-Quality Management Audits in Nuclear Medicine (QUANUM). This program covers all aspects of nuclear medicine practices including, but not limited to, clinical practice, management, operations, and services. The QUANUM program, which includes quality standards detailed in relevant checklists, aims at introducing a culture of comprehensive quality audit processes that are patient oriented, systematic, and outcome based. This paper will focus on the impact of the implementation of QUANUM on daily routine practices in audited centers. Thirty-seven centers, which had been externally audited by experts under IAEA auspices at least 1 year earlier, were invited to run an internal audit using the QUANUM checklists. The external audits also served as training in quality management and the use of QUANUM for the local teams, which were responsible of conducting the internal audits. Twenty-five out of the 37 centers provided their internal audit report, which was compared with the previous external audit. The program requires that auditors score each requirement within the QUANUM checklists on a scale of 0-4, where 0-2 means nonconformance and 3-4 means conformance to international regulations and standards on which QUANUM is based. Our analysis covering both general and clinical areas assessed changes on the conformance status on a binary manner and the level of conformance scores. Statistical analysis was performed using nonparametric statistical tests. The evaluation of the general checklists showed a global improvement on both the status and the levels of conformances (P < 0.01). The evaluation of the requirements by checklist also showed a significant improvement in all, with the exception of Hormones and Tumor marker determinations, where changes were not significant. Of the 25 evaluated institutions, 88% (22 of 25) and 92% (23 of 25) improved their status and levels of conformance, respectively. Fifty-five requirements, on average, increased from nonconformance to conformance status. In 8 key areas, the number of improved requirements was well above the average: Administration & Management (checklist 2); Radiation Protection & Safety (checklist 4); General Quality Assurance system (checklist 6); Imaging Equipment Quality Assurance or Quality Control (checklist 7); General Diagnostic (checklist 9); General Therapeutic (checklist 12); Radiopharmacy Level 1 (checklist 14); and Radiopharmacy Level 2 (checklist 15). Analysis of results related to clinical activities showed an overall positive impact on both the status and the level of conformance to international standards. Similar results were obtained for the most frequently performed clinical imaging and therapeutic procedures. Our study shows that the implementation of a comprehensive quality management system through the IAEA QUANUM program has a positive impact on nuclear medicine practices.
(Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.)
Databáze: MEDLINE