Automated Detection and Classification of Corneal Haze Using Optical Coherence Tomography in Patients With Keratoconus After Cross-Linking.

Autor: Dhaini AR; Department of Computer Science, American University of Beirut, Beirut, Lebanon., Abdul Fattah M; Department of Ophthalmology, American University of Beirut Medical Center, Beirut, Lebanon., El-Oud SM; Department of Computer Science, American University of Beirut, Beirut, Lebanon., Awwad ST; Department of Ophthalmology, American University of Beirut Medical Center, Beirut, Lebanon.
Jazyk: angličtina
Zdroj: Cornea [Cornea] 2018 Jul; Vol. 37 (7), pp. 863-869.
DOI: 10.1097/ICO.0000000000001570
Abstrakt: Purpose: To evaluate a proposed technology for offering objective grading and mapping of corneal haze as detected by corneal spectral domain optical coherence tomography after corneal cross-linking.
Methods: This was a retrospective study to evaluate corneal optical coherence tomography images performed on 44 eyes of 44 patients who underwent corneal cross-linking between January 2014 and May 2015, at the American University of Beirut Medical Center.
Results: Overall average brightness of the cornea was markedly increased from 43.4% (±6.0) at baseline to 50.2% (±4.4) at 1 month, 47.9% (±4.4) at 3 months, and 46.4% (±5.7) at 6 months with P <0.001, <0.001, and 0.005, respectively. In the anterior stroma, the average brightness significantly increased at 1, 3, and 6 months with values of 54.8% (±3.9), 52.5% (±5.2), and 49.7% (±6.9) with P <0.001, <0.001, and 0.003, respectively. In the mid stroma, the change was clinically significant at 1 and 3 months, whereas in the posterior stroma, it was only significant at 1 month compared with baseline (P = 0.003). Overall, haze was mostly present at 1 month after surgery in all regions, especially in the anterior (32.1%; ±19.2) and mid stromal regions (9.1%; ±18.8), P <0.001 and 0.001, respectively. In contrast, haze in the posterior stromal region peaks at 3 and 6 months after surgery.
Conclusions: Anterior stromal haze was the greatest in intensity and area and it was present for a longer time span than mid and posterior stromal haze. At 12 months, the anterior stroma had still more haze intensity than preoperatively. This image-based software can provide objective and valuable quantitative measurements of corneal haze, which may impact clinical decision-making after different corneal surgeries.
Databáze: MEDLINE