Towards bedside washing of stored red blood cells: a prototype of a simple apparatus based on microscale sedimentation in normal gravity.
Autor: | Khanal G; Department of Biomedical Engineering, University of Houston, Houston, TX, USA., Huynh RA; Department of Biomedical Engineering, University of Houston, Houston, TX, USA., Torabian K; Department of Biomedical Engineering, University of Houston, Houston, TX, USA., Xia H; Department of Biomedical Engineering, University of Houston, Houston, TX, USA., Vörös E; Department of Biomedical Engineering, University of Houston, Houston, TX, USA., Shevkoplyas SS; Department of Biomedical Engineering, University of Houston, Houston, TX, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | Vox sanguinis [Vox Sang] 2018 Jan; Vol. 113 (1), pp. 31-39. Date of Electronic Publication: 2017 Oct 25. |
DOI: | 10.1111/vox.12605 |
Abstrakt: | Background and Objectives: Infusion of by-products of red blood cell (RBC) storage-induced degradation as well as of the residual plasma proteins and the anticoagulant-preservative solution contained in units of stored blood serve no therapeutic purpose and may be harmful to some patients. Here, we describe a prototype of a gravity-driven system for bedside washing of stored RBCs. Materials and Methods: Stored RBCs were diluted to 10% haematocrit (Hct) with normal saline, matching the conventional washing procedure. The dilute RBC suspensions were passed through a column of coiled tubing to allow RBC sedimentation in normal gravity, thus separating them from the washing solution. Washed RBCs were collected using bifurcations located along the tubing. Washing efficiency was quantified by measuring Hct, morphology, deformability, free haemoglobin and total-free protein. Results: The gravity-driven washing system operating at 0·5 ml/min produced washed RBCs with final Hct of 36·7 ± 3·4% (32·3-41·2%, n = 10) and waste Hct of 3·4 ± 0·7% (2·4-4·3%, n = 10), while removing 80% of free haemoglobin and 90% of total-free protein. Washing improved the ability of stored RBCs to perfuse an artificial microvascular network by 20%. The efficiency of washing performed using the gravity-driven system was not significantly different than that of conventional centrifugation. Conclusions: This proof-of-concept study demonstrates the feasibility of washing stored RBCs using a simple, disposable system with efficiency comparable to that of conventional centrifugation, and thus represents a significant first step towards enabling low-cost washing of stored blood at bedside. (© 2017 International Society of Blood Transfusion.) |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |