Strength properties of soldered joints for a gold-palladium alloy and a palladium alloy.

Autor: Lorenzana RE, Staffanou RS, Marker VA, Okabe T
Jazyk: angličtina
Zdroj: The Journal of prosthetic dentistry [J Prosthet Dent] 1987 Apr; Vol. 57 (4), pp. 450-4.
DOI: 10.1016/0022-3913(87)90013-8
Abstrakt: Strength of a soldered palladium alloy, PGC (Engelhard Corp.), and a soldered medium gold alloy, PGX (Engelhard Corp.), was examined. The results obtained were as follows: Highest strength was observed with postsoldered specimens of PGC alloy. Microstructural examination of postsoldered specimens revealed nearly pore-free solder joints with PGC and PGX alloys, and fracture appeared at the solder-alloy interface with PGC and PGX alloys. Microstructural examination of presoldered and presoldered/thermocycled specimens revealed that presoldered specimens of PGC and PGX alloys exhibited intrasolder fracture; PGX solder joints had considerably less porosity, which may explain the equivalent bond strengths of all the soldered specimens and the yield point of the controls; PGC solder joints exhibited large quantities of pores, which may explain the lower strength; pores observed in PGC alloy may be the result of the high fusing temperature of the solder; and these results indicate a need to develop a new presolder for PGC. The best result was obtained with postsoldered specimens of the PGC alloy. However, for PGX alloy, either postsolder or presolder techniques can be used.