Polyacylurethanes as Novel Degradable Cell Carrier Materials for Tissue Engineering.

Autor: Jovanovic D; Department of Polymer Science, Faculty of Mathematics and Natural Sciences, Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands. d.jovanovic@rug.nl., Roukes FV; Department of Polymer Science, Faculty of Mathematics and Natural Sciences, Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands. frans_roukes@hotmail.com., Löber A; Institute for Bioengineering, Martin-Luther University, Halle 06108, Germany. andrea_loeber@gmx.de., Engels GE; Department of Biomedical Engineering, University Medical Centre Groningen, University of Groningen, A. Deusinglaan 1, building 3215, FB40, 9713AV Groningen, The Netherlands. g.e.engels@med.umcg.nl., Oeveren WV; Department of Biomedical Engineering, University Medical Centre Groningen, University of Groningen, A. Deusinglaan 1, building 3215, FB40, 9713AV Groningen, The Netherlands. w.van.Oeveren@med.umcg.nl., Seijen XJGV; Department of Pathology and Medical Biology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. x_gallego@hotmail.com., Luyn MJAV; Department of Pathology and Medical Biology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. m.j.a.van.Luyn@med.umcg.nl., Harmsen MC; Department of Pathology and Medical Biology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. m.c.harmsen@med.umcg.nl., Schouten AJ; Department of Polymer Science, Faculty of Mathematics and Natural Sciences, Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands. a.j.schouten@rug.nl.
Jazyk: angličtina
Zdroj: Materials (Basel, Switzerland) [Materials (Basel)] 2011 Oct 06; Vol. 4 (10), pp. 1705-1727. Date of Electronic Publication: 2011 Oct 06.
DOI: 10.3390/ma4101705
Abstrakt: Polycaprolactone (PCL) polyester and segmented aliphatic polyester urethanes based on PCL soft segment have been thoroughly investigated as biodegradable scaffolds for tissue engineering. Although proven beneficial as long term implants, these materials degrade very slowly and are therefore not suitable in applications in which scaffold support is needed for a shorter time. A recently developed class of polyacylurethanes (PAUs) is expected to fulfill such requirements. Our aim was to assess in vitro the degradation of PAUs and evaluate their suitability as temporary scaffold materials to support soft tissue repair. With both a mass loss of 2.5-3.0% and a decrease in molar mass of approx. 35% over a period of 80 days, PAUs were shown to degrade via both bulk and surface erosion mechanisms. Fourier Transform Infra Red (FTIR) spectroscopy was successfully applied to study the extent of PAUs microphase separation during in vitro degradation. The microphase separated morphology of PAU1000 (molar mass of the oligocaprolactone soft segment = 1000 g/mol) provided this polymer with mechano-physical characteristics that would render it a suitable material for constructs and devices. PAU1000 exhibited excellent haemocompatibility in vitro. In addition, PAU1000 supported both adhesion and proliferation of vascular endothelial cells and this could be further enhanced by pre-coating of PAU1000 with fibronectin (Fn). The contact angle of PAU1000 decreased both with in vitro degradation and by incubation in biological fluids. In endothelial cell culture medium the contact angle reached 60°, which is optimal for cell adhesion. Taken together, these results support the application of PAU1000 in the field of soft tissue repair as a temporary degradable scaffold.
Databáze: MEDLINE