Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses.

Autor: Vilar C; Cataract Division, Brasília Ophthalmologic Hospital (HOB), Brasília-DF, Brazil.; Renato Ambrosio Ophthalmologic Research Center (CEORA)., Hida WT; Cataract Division, Brasília Ophthalmologic Hospital (HOB), Brasília-DF, Brazil.; Renato Ambrosio Ophthalmologic Research Center (CEORA).; Ophthalmology Department, São Paulo University - USP, São Paulo-SP, Brazil., de Medeiros AL; Cataract Division, Brasília Ophthalmologic Hospital (HOB), Brasília-DF, Brazil.; Renato Ambrosio Ophthalmologic Research Center (CEORA)., Magalhães KRP; Renato Ambrosio Ophthalmologic Research Center (CEORA)., de Moraes Tzelikis PF; Cataract Division, Brasília Ophthalmologic Hospital (HOB), Brasília-DF, Brazil.; Renato Ambrosio Ophthalmologic Research Center (CEORA)., Chaves MAPD; Renato Ambrosio Ophthalmologic Research Center (CEORA).; Cataract Division, ProVisão, João Pessoa-PB, Brazil., Motta AFP; Renato Ambrosio Ophthalmologic Research Center (CEORA).; Ophthalmology Department, São Paulo University - USP, São Paulo-SP, Brazil., Carricondo PC; Cataract Division, Brasília Ophthalmologic Hospital (HOB), Brasília-DF, Brazil.; Renato Ambrosio Ophthalmologic Research Center (CEORA).; Ophthalmology Department, São Paulo University - USP, São Paulo-SP, Brazil., Alves MR; Ophthalmology Department, São Paulo University - USP, São Paulo-SP, Brazil., Nosé W; Ophthalmology Department, Paulista Medical School - UNIFESP, São Paulo-SP, Brazil.
Jazyk: angličtina
Zdroj: Clinical ophthalmology (Auckland, N.Z.) [Clin Ophthalmol] 2017 Aug 01; Vol. 11, pp. 1393-1397. Date of Electronic Publication: 2017 Aug 01 (Print Publication: 2017).
DOI: 10.2147/OPTH.S139909
Abstrakt: Purpose: To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof ® PanOptix ® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof ® Restor ® SV25T0 in dominant eye and Acrysof ® Restor ® SN6AD1 in the nondominant eye.
Methods: This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve.
Results: Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision.
Conclusion: Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions.
Competing Interests: Disclosure The authors report no conflicts of interest in this work.