Front-End Electron Transfer Dissociation Coupled to a 21 Tesla FT-ICR Mass Spectrometer for Intact Protein Sequence Analysis.

Autor: Weisbrod CR; National High Magnetic Field Laboratory (NHMFL), 1800 East Paul Dirac Dr., Tallahassee, FL, 32310, USA. weisbrod@magnet.fsu.edu., Kaiser NK; National High Magnetic Field Laboratory (NHMFL), 1800 East Paul Dirac Dr., Tallahassee, FL, 32310, USA., Syka JEP; Thermo Fisher Scientific, San Jose, CA, 95134, USA., Early L; Thermo Fisher Scientific, San Jose, CA, 95134, USA., Mullen C; Thermo Fisher Scientific, San Jose, CA, 95134, USA., Dunyach JJ; Thermo Fisher Scientific, San Jose, CA, 95134, USA., English AM; Department of Chemistry, University of Virginia, McCormick Road, P.O. Box 400319, Charlottesville, VA, 22904-4319, USA., Anderson LC; National High Magnetic Field Laboratory (NHMFL), 1800 East Paul Dirac Dr., Tallahassee, FL, 32310, USA., Blakney GT; National High Magnetic Field Laboratory (NHMFL), 1800 East Paul Dirac Dr., Tallahassee, FL, 32310, USA., Shabanowitz J; Department of Chemistry, University of Virginia, McCormick Road, P.O. Box 400319, Charlottesville, VA, 22904-4319, USA., Hendrickson CL; National High Magnetic Field Laboratory (NHMFL), 1800 East Paul Dirac Dr., Tallahassee, FL, 32310, USA.; Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL, 32306, USA., Marshall AG; National High Magnetic Field Laboratory (NHMFL), 1800 East Paul Dirac Dr., Tallahassee, FL, 32310, USA.; Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL, 32306, USA., Hunt DF; Department of Chemistry, University of Virginia, McCormick Road, P.O. Box 400319, Charlottesville, VA, 22904-4319, USA.; Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA, 22908, USA.
Jazyk: angličtina
Zdroj: Journal of the American Society for Mass Spectrometry [J Am Soc Mass Spectrom] 2017 Sep; Vol. 28 (9), pp. 1787-1795. Date of Electronic Publication: 2017 Jul 18.
DOI: 10.1007/s13361-017-1702-3
Abstrakt: High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. Graphical Abstract ᅟ.
Databáze: MEDLINE