Structural Parameters of the Proximal Femur by 3-Dimensional Dual-Energy X-ray Absorptiometry Software: Comparison With Quantitative Computed Tomography.

Autor: Clotet J; Musculoskeletal Unit, Galgo Medical, Barcelona, Spain., Martelli Y; Musculoskeletal Unit, Galgo Medical, Barcelona, Spain., Di Gregorio S; CETIR Grup Mèdic, Barcelona, Spain., Del Río Barquero LM; CETIR Grup Mèdic, Barcelona, Spain., Humbert L; Musculoskeletal Unit, Galgo Medical, Barcelona, Spain. Electronic address: ludohumberto@gmail.com.
Jazyk: angličtina
Zdroj: Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry [J Clin Densitom] 2018 Oct - Dec; Vol. 21 (4), pp. 550-562. Date of Electronic Publication: 2017 Jun 16.
DOI: 10.1016/j.jocd.2017.05.002
Abstrakt: Structural parameters of the proximal femur evaluate the strength of the bone and its susceptibility to fracture. These parameters are computed from dual-energy X-ray absorptiometry (DXA) or from quantitative computed tomography (QCT). The 3-dimensional (3D)-DXA software solution provides 3D models of the proximal femur shape and bone density from anteroposterior DXA scans. In this paper, we present and evaluate a new approach to compute structural parameters using 3D-DXA software. A cohort of 60 study subjects (60.9 ± 14.7 yr) with DXA and QCT examinations was collected. 3D femoral models obtained by QCT and 3D-DXA software were aligned using rigid registration techniques for comparison purposes. Geometric, cross-sectional, and volumetric structural parameters were computed at the narrow neck, intertrochanteric, and lower shaft regions for both QCT and 3D-DXA models. The accuracy of 3D-DXA structural parameters was evaluated in comparison with QCT. Correlation coefficients (r) between geometric parameters computed by QCT and 3D-DXA software were 0.86 for the femoral neck axis length and 0.71 for the femoral neck shaft angle. Correlation coefficients ranged from 0.86 to 0.96 for the cross-sectional parameters and from 0.84 to 0.97 for the volumetric structural parameters. Our study demonstrated that accurate estimates of structural parameters for the femur can be obtained from 3D-DXA models. This provides clinicians with 3D indexes related to the femoral strength from routine anteroposterior DXA scans, which could potentially improve osteoporosis management and fracture prevention.
(Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.)
Databáze: MEDLINE