Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.
Autor: | Dharmalingam A; Department of Nuclear Medicine Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India., Pawar SU; Department of Nuclear Medicine Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India., Parelkar SV; Department of Pediatric Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India., Shetye SS; Department of Nuclear Medicine Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India., Ghorpade MK; Department of Nuclear Medicine Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India., Tilve GH; Department of Nuclear Medicine Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India. |
---|---|
Jazyk: | angličtina |
Zdroj: | Indian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, India [Indian J Nucl Med] 2017 Apr-Jun; Vol. 32 (2), pp. 93-97. |
DOI: | 10.4103/0972-3919.202240 |
Abstrakt: | Context: The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. Aims: The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Settings and Design: Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Materials and Methods: Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. Statistical Analysis Used: MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. Results: There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. Conclusions: The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child. Competing Interests: There are no conflicts of interest |
Databáze: | MEDLINE |
Externí odkaz: |